Measurement of neural respiratory drive via parasternal intercostal electromyography in healthy adult subjects.

نویسندگان

  • V MacBean
  • C Hughes
  • G Nicol
  • C C Reilly
  • G F Rafferty
چکیده

Neural respiratory drive, quantified by the parasternal intercostal muscle electromyogram (EMGpara), provides a sensitive measure of respiratory system load-capacity balance. Reference values for EMGpara-based measures are lacking and the influence of individual anthropometric characteristics is not known. EMGpara is conventionally expressed as a percentage of that obtained during a maximal inspiratory effort (EMGpara%max), leading to difficulty in applying the technique in subjects unable to reliably perform such manoeuvres. To measure EMGpara in a large, unselected cohort of healthy adult subjects in order to evaluate relevant technical and anthropometric factors. Surface second intercostal space EMGpara was measured during resting breathing and maximal inspiratory efforts in 63 healthy adult subjects, median (IQR) age 31.0 (25.0-47.0) years, 28 males. Detailed anthropometry, spirometry and respiratory muscle strength were also recorded. Median (IQR EMGpara was 4.95 (3.35-6.93) µV, EMGpara%max 4.95 (3.39-8.65)% and neural respiratory drive index (NRDI, the product of EMGpara%max and respiratory rate) was 73.62 (46.41-143.92) %.breath/min. EMGpara increased significantly to 6.28 (4.26-9.93) µV (p  <  0.001) with a mouthpiece, noseclip and pneumotachograph in situ. Median (IQR) EMGpara was higher in female subjects (5.79 (4.42-7.98) µV versus 3.56 (2.81-5.35) µV, p  =  0.003); after controlling for sex neither EMGpara, EMGpara%max or NRDI were significantly related to anthropometrics, age or respiratory muscle strength. In subjects undergoing repeat measurements within the same testing session (n  =  48) or on a separate occasion (n  =  19) similar repeatability was observed for both EMGpara and EMGpara%max. EMGpara is higher in female subjects than males, without influence of other anthropometric characteristics. Reference values are provided for EMGpara-derived measures. Expressing EMGpara as a percentage of maximum confers no advantage with respect to measurement repeatability, expanding the potential application of the technique. Raw EMGpara is a useful marker of respiratory system load-capacity balance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Respiratory Muscle Electromyography between Adolescent Idiopathic Scoliosis and Healthy Subjects

Purpose: Scoliosis is one of the most common spinal deformities that affect chest wall mechanics. Scoliosis results in ventilator disorders and respiratory muscle weakness. However, the mechanism of these disorders is still unknown. The main objective of this study was to identify the intensity of respiratory muscles activity in patients with idiopathic scoliosis compare with healthy indi...

متن کامل

Is parasternal intercostal EMG an accurate surrogate of respiratory neural drive and biomarker of dyspnea during cycle exercise testing?

Recent evidence suggests that surface electromyography of the parasternal intercostals (EMGpara) can be a non-invasive alternative to diaphragmatic EMG (EMGdi) for estimating neural respiratory drive (NRD) during cardiopulmonary exercise testing (CPET). The purpose of this study was to determine if non-respiratory muscles influence EMGpara by having subjects place their hands on (Hon) and off (...

متن کامل

Measurement of parasternal intercostal electromyogram during an infective exacerbation in patients with cystic fibrosis.

The parasternal intercostal muscle electromyogram (sEMGpara) is a measure of neural respiratory drive and reflects lung disease severity in stable cystic fibrosis (CF). The aim of the study was to measure sEMGpara in acute infective exacerbations of CF and compare changes in sEMGpara with those in conventional lung function measures. 12 patients with CF admitted to hospital with an acute chest ...

متن کامل

Nocturnal asthma monitoring by chest wall electromyography.

RATIONALE Patients with suboptimal asthma control often have nocturnal symptoms which wake them, causing sleep fragmentation. OBJECTIVES It was hypothesised that symptomatic patients were more accurately identified by measuring respiratory effort using chest wall electromyography than by pulmonary function testing. METHODS Nocturnal electrical activity of the parasternal intercostal muscles...

متن کامل

Blunted perception of neural respiratory drive and breathlessness in patients with cystic fibrosis

The electromyogram recorded from the diaphragm (EMGdi) and parasternal intercostal muscle using surface electrodes (sEMGpara) provides a measure of neural respiratory drive (NRD), the magnitude of which reflects lung disease severity in stable cystic fibrosis. The aim of this study was to explore perception of NRD and breathlessness in both healthy individuals and patients with cystic fibrosis....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 2016