Ultrasensitive beam deflection measurement via interferometric weak value amplification.

نویسندگان

  • P Ben Dixon
  • David J Starling
  • Andrew N Jordan
  • John C Howell
چکیده

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power-Recycled Weak-Value-Based Metrology We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling

Power-Recycled Weak-Value-Based Metrology Report Title We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in all the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-tonoise ratio of the deflecti...

متن کامل

Technical Advantages for Weak-Value Amplification: When Less Is More

The technical merits of weak-value-amplification techniques are analyzed. We consider models of several different types of technical noise in an optical context and show that weak-value-amplification techniques (which only use a small fraction of the photons) compare favorably with standard techniques (which use all of them). Using the Fisher-information metric, we demonstrate that weak-value t...

متن کامل

Power-recycled weak-value-based metrology.

We improve the precision of the interferometric weak-value-based beam deflection measurement by introducing a power recycling mirror, creating a resonant cavity. This results in all the light exiting to the detector with a large deflection, thus eliminating the inefficiency of the rare postselection. The signal-to-noise ratio of the deflection is itself magnified by the weak value. We discuss w...

متن کامل

Picoradian deflection measurement with an interferometric quasi-autocollimator using weak value amplification.

We present an "interferometric quasi-autocollimator" that employs weak value amplification to measure angular deflections of a target mirror. The device has been designed to be insensitive to all translations of the target. We present a conceptual explanation of the amplification effect used by the device. An implementation of the device demonstrates sensitivities better than 10 picoradians per...

متن کامل

Interferometric weak value deflections: Quantum and classical treatments

Weak values [1] have presented or inspired intriguing possibilities for precision measurement. A recent example is by Hosten and Kwiat [2], where they were able to amplify the deflections arising from the spin Hall effect of light. The light fields used in their experiment, as well as in Ref. [3], were coherent quasiclassical fields and no apparent quantum mechanical system was employed in eith...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review letters

دوره 102 17  شماره 

صفحات  -

تاریخ انتشار 2009