Real-ear-to-coupler difference predictions as a function of age for two coupling procedures.

نویسندگان

  • Marlene P Bagatto
  • Susan D Scollie
  • Richard C Seewald
  • K Shane Moodie
  • Brenda M Hoover
چکیده

The predicted real-ear-to-coupler difference (RECD) values currently used in pediatric hearing instrument prescription methods are based on 12-month age range categories and were derived from measures using standard acoustic immittance probe tips. Consequently, the purpose of this study was to develop normative RECD predicted values for foam/acoustic immittance tips and custom earmolds across the age continuum. To this end, RECD data were collected on 392 infants and children (141 with acoustic immittance tips, 251 with earmolds) to develop normative regression equations for use in deriving continuous age predictions of RECDs for foam/acoustic immittance tips and earmolds. Owing to the substantial between-subject variability observed in the data, the predictive equations of RECDs by age (in months) resulted in only gross estimates of RECD values (i.e., within +/- 4.4 dB for 95% of acoustic immittance tip measures; within +/- 5.4 dB in 95% of measures with custom earmolds) across frequency. Thus, it is concluded that the estimates derived from this study should not be used to replace the more precise individual RECD measurements. Relative to previously available normative RECD values for infants and young children, however, the estimates derived through this study provide somewhat more accurate predicted values for use under those circumstances for which individual RECD measurements cannot be made.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel design for all-optical NAND/NOR/XOR gates based on nonlinear directional coupler

In this paper a novel all-optical logic NAND, NOR and XOR gate based on nonlinear directional coupler theory is demonstrated. We use the identical structure which contains three waveguides, for designing these gates; the only difference however, is the power of inputs light beam. In other words, while a beam with 4 W/μm in power considered as logical one, the output is NAND gate and if a beam w...

متن کامل

A novel design for all-optical NAND/NOR/XOR gates based on nonlinear directional coupler

In this paper a novel all-optical logic NAND, NOR and XOR gate based on nonlinear directional coupler theory is demonstrated. We use the identical structure which contains three waveguides, for designing these gates; the only difference however, is the power of inputs light beam. In other words, while a beam with 4 W/μm in power considered as logical one, the output is NAND gate and if a beam w...

متن کامل

Effects of tubing length and coupling method on hearing threshold and real-ear to coupler difference measures.

PURPOSE This tutorial demonstrates the effects of tubing length and coupling type (i.e., foam tip or personal earmold) on hearing threshold and real-ear-to-coupler difference (RECD) measures. METHOD Hearing thresholds from 0.25 kHz through 8 kHz are reported at various tubing lengths for 28 normal-hearing adults between the ages of 22 and 31 years. RECD values are reported for 14 of the adult...

متن کامل

The Design of half-subtractor Logic Function Based on Nonlinear Directional Coupler

In this paper a novel design of all-optical half-subtractor based on nonlinear directional coupler is proposed. By using four waveguides and appropriately adjusting the refractive indices and selecting the proper length of waveguides, halfsubtractor function can be obtained. The operation of this function is simulated by RSoft CAD-Layout (BeamPROP) simulator. The simulation results confirm the ...

متن کامل

Target-matched insertion gain derived from three different hearing aid selection procedures.

Three hearing aid selection procedures were compared to determine if any one was superior in producing prescribed real-ear insertion gain. For each of three subject groups, 12 in-the-ear style hearing aids with Class D circuitry and similar dispenser controls were ordered from one of three manufacturers. Subject groups were classified based on the type of information included on the hearing aid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 13 8  شماره 

صفحات  -

تاریخ انتشار 2002