A comparative dosimetric study of volumetric-modulated arc therapy vs. fixed field intensity-modulated radiotherapy in postoperative irradiation of stage IB-IIA high-risk cervical cancer

نویسندگان

  • LILI QIAO
  • JIAN CHENG
  • NING LIANG
  • JIAN XIE
  • HUI LUO
  • JIANDONG ZHANG
چکیده

The aim of the present study was to compare the dosimetry features of volumetric-modulated arc therapy (VMAT) and fixed field intensity-modulated radiotherapy (f-IMRT) in postoperative irradiation of stage IB-IIA high-risk cervical cancer. Fifteen patients exhibiting stage IB-IIA high-risk cervical cancer, who had been treated with postoperative adjuvant concurrent radiochemotherapy, were selected. The clinical target volume (CTV) and organs at risk (OARs) were delineated according to contrast computed tomography images. The planning target volume (PTV) was subsequently produced by using 1 cm uniform expansion of the CTV. The treatment plans were intended to deliver 50 Gy in 25 fractions. The OARs that were contoured included the bladder, rectum, small bowel and femoral heads. Dose volume histograms were used to evaluate the dose distribution in the PTV and OARs. VMAT and f-IMRT treatment plans resulted in similar dose coverage of the PTV. VMAT was superior to f-IMRT in conformity (P<0.05), and resulted in a reduction of OARs irradiated at high dose levels (V40 and V50) compared with f-IMRT (P<0.05), particularly for the bladder. However, the doses of low levels (V10 and V20) delivered to OARs with f-IMRT were slightly reduced compared with VMAT (P<0.05). For ambilateral femoral heads, VMAT demonstrated improved sparing compared with f-IMRT, with regard to D5 (P<0.05). Furthermore, VMAT treatment plans revealed a significant reduction in monitor units (MU) and treatment time. VMAT techniques exhibited similar PTV coverage compared with f-IMRT. At doses of high levels delivered to OARs, VMAT demonstrated improved sparing compared with f-IMRT, particularly for the bladder, while significantly reducing treatment time and MU number.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Dosimetric benefits of intensity‐modulated radiotherapy and volumetric‐modulated arc therapy in the treatment of postoperative cervical cancer patients

As the advantage of using complex volumetric-modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of 15 postoperative cervical cancer pati...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.&nbsp; Material...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016