چکیده
We reviewed 1567 elective knee replacements performed between 1980 and 1990, using either the Total Condylar prosthesis with an all-plastic tibial component, or the Kinematic prosthesis which has a metal tibial tray. The ten-year probability of survival was 92.1% for the Total Condylar design and 87.9% for the Kinematic. The difference was mainly due to 16 revisions required in the Kinematic series for fracture of the metal base-plate. This was the most common cause of aseptic failure in this group. These fractures were strongly associated with a preoperative varus deformity (hazard ratio (HR) 8.8) and there was a slightly increased risk in males (HR 1.9) and in osteoarthritic knees (HR 1.8). In the nine fractures which occurred within four years of primary implantation (group 1), failure to correct adequately a preoperative varus deformity and the use of a bone graft to correct such a deformity were both strongly associated with fracture (HR 13.9 and 15.8, respectively). In eight fractures which occurred more than five years after primary replacement (group 2) we could detect no significant risk factors. Early complications occurred in two patients after the 16 revision procedures for tray fracture. One had a deep infection and the other refracture of the tray.
منابع مشابه
Same-Level Fracture of the Tibial Metal Tray and Polyethylene Insert After Total Knee Arthroplasty.
The authors report a case of failure fracture of the tibial metal tray and polyethylene insert at the same level in a 73-year-old woman 10 years after total knee arthroplasty using the AMK Total Knee System (DePuy, Warsaw, Indiana). Causes of this fracture are analyzed and discussed, with the focus on the importance of component design, position, and size. The overall aim of this case report is...
متن کاملThermal Analysis of the Tibial Cement Interface with Modern Cementing Technique
BACKGROUND The major cause of cemented Total Knee Arthroplasty (TKA) failure is aseptic loosening of the tibial component necessitating revision surgery. Recently, multiple techniques have been described to maximize cement penetration depth and density in the proximal tibia during TKA to potentially avoid early loosening. While cement polymerisation is an exothermic reaction, minimal investigat...
متن کاملCase series report: Early cement-implant interface fixation failure in total knee replacement.
BACKGROUND Early failure in cemented total knee replacement (TKR) due to aseptic loosening is uncommon. A small number of early failures requiring revision were observed at one hospital due to observed cement-implant fixation failure. The purpose of this case series is to report and identify possible causes for these early failures. METHODS Between May 2005 and December 2010, 3048 primary TKR...
متن کاملPolished Cobalt-Chrome vs Titanium Tibial Trays in Total Knee Replacement (a Comparison using the PFC Sigma System)
Fixed-bearing total knee arthroplasty components can cause wear debris due to fretting micromotion between the polyethylene insert and the metal tibial tray, possibly leading to osteolysis and implant failure. This study compared the effects of either a highly polished cobalt-chrome (CoCr) or titanium tibial tray in patients receiving the PFC. Sigma® posterior stabilized knee system with a mode...
متن کاملEffect of Tibial Tray Malalignment on Micromotion and Subsidence: A Preliminary Report
Malalignment of the tibial tray in total knee arthroplasty has been linked to several complications including tibial tray subsidence, leading to revision surgery. However, quantitative biomechanical evidence to directly support the mechanism of failure is not available. We developed a model to study tibial tray micromotion and subsidence in vitro under multiaxial physiological loading condition...