A Necessary Condition for Consistency of Noisy ACC00-SHT1049 Experimental Closed-Loop Frequency-Response Data with SISO Coprime Factor Models

نویسنده

  • Benoit Boulet
چکیده

This note introduces a necessary condition for the model/data consistency problem with perturbed coprime factorizations and closed-loop noisy frequency-response measurements. The necessary condition involves the computation of structured singular values of complex linear fractional transformations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Necessary Conditions for Consistency of Noise-Free, ACC00-IEEE1403 Closed-Loop Frequency-Response Data with Coprime Factor Models

A basic requirement of robust control theory is that a nominal model and an uncertainty model be available for the plant. The assumption is that the plant can be modeled by at least one of the perturbations of the nominal model in the uncertainty set. This raises the problem of constructing such an uncertainty set that would be consistent with a given set of experimental input-output data. This...

متن کامل

Consistency of Open-Loop Experimental Frequency- Response Data with Coprime Factor Plant Models

The model/data consistency problem for coprime factorizations considered here is this: Given some possibly noisy frequency-response data obtained by running open-loop experiments on a system, show that these data are consistent with a given family of perturbed coprime factor models and a timedomain L1 noise model. In the noise-free open-loop case, the model/data consistency problem boils down t...

متن کامل

Coprime Factor Based Closed-Loop Model Validation Applied to a Flexible Structure

This paper addresses the problem of checking the consistency of experimental closed-loop frequency-domain data with uncertainty models that are structured using coprime factorizations. The uncertainty models presented in this paper use the knowledge of a stabilizing feedback controller to structure and formulate the uncertainty on a model. Subsequently, the controller dependent coprime factor u...

متن کامل

Non-parametric H∞ control synthesis with suboptimal controller sets

The effectiveness of norm-based control methodologies heavily relies on the quality of the model that describes the dynamic behavior of the plant. In practical applications, the requirement to accurately describe the system at hand often results in high-order plant-models. On the other hand, low-order models are desired to end-up with low-order controllers that reduce implementational costs. Th...

متن کامل

System Identification Based on Frequency Response Noisy Data

In this paper, a new algorithm for system identification based on frequency response is presented. In this method, given a set of magnitudes and phases of the system transfer function in a set of discrete frequencies, a system of linear equations is derived which has a unique and exact solution for the coefficients of the transfer function provided that the data is noise-free and the degrees of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999