Gas Detection with a Micro FTIR Spectrometer in the MIR Region

نویسندگان

  • T. Scharf
  • D. Briand
  • S. Bühler
  • O. Manzardo
  • H. P. Herzig
  • N. F. de Rooij
چکیده

We report on the application of a silicon micromachined lamellar grating interferometer in a Fourier Transform Infrared (FTIR) spectrometer for the detection of gases in the mid-infrared (MIR) region. The FTIR spectrometer was equipped with MIR optical fibers for light coupling. Gas measurements in the MIR region were focused on specific gases (CO2, CH4) in order to determine the limit of detection and the selectivity that could be obtained using such a micro-spectrometer. The influence of humidity on the gas response has also been investigated. Using two different spectral regions we were able to detect concentrations of carbon dioxide over a span from 100 ppm to 9000 ppm with a theoretical detection limit evaluated at 10 ppm. The performed gas measurements showed the proof of principle of a miniaturised FTIR gas analyzer based on a micromachined spectrometer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Assay of miR-223, miR-145, and miR-16 by a Novel Method of Mimic PCR in Serum of Breast Cancer Patients

The role of microRNAs (miRs) is shown as a biomarker whose expression level changes have been associated with cancer development and progression. Circulating miRNAs have been postulated as biomarkers for breast cancer. Detection and diagnosis of miRNA markers could provide an improved and sensitive method in the clinical application. In this study, we applied and improved the effective approach...

متن کامل

The Gas Phase Oxidation of Acetaldehyde Reaction Mechanism and Kinetics

The mechanism of the low temperature oxidation of gaseous acetaldehyde was investigated in the temperature range of 1 50-400?°C. The minor, intermediate and major products were identified and measured quantitatively by sampling directly into the ionization chamber of an MS10-C2 mass spectrometer from the reactor. The formation of H2O, CO, CO2, HCOOH, H2, HCHO, CH3COOH and CH3OH as the major pro...

متن کامل

FTIR-Microspectroscopy Detection of Metronidazole Teratogenic Effects on Mice Fetus

Metronidazole is used to treat trichomoniasis, bacterial vaginosis, and other diseases. There are controversy aspects about its teratogenicity. A teratogenic agent can alter morphology or subsequent function of the fetus. The aim of this study was to examine an alternative method for the recognition of the mechanism or the bimolecular potential changes in mice fetus caused by Metronidazole usin...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

FTIR-Microspectroscopy Detection of Metronidazole Teratogenic Effects on Mice Fetus

Metronidazole is used to treat trichomoniasis, bacterial vaginosis, and other diseases. There are controversy aspects about its teratogenicity. A teratogenic agent can alter morphology or subsequent function of the fetus. The aim of this study was to examine an alternative method for the recognition of the mechanism or the bimolecular potential changes in mice fetus caused by Metronidazole usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009