Evaluation of Correction Factors Applied in Photon Calibration of NIS TE Neutron Ionization Chambers
نویسنده
چکیده
Calibrations of two tissue equivalent (TE) ionization chamber were made in five photon beams (100 kV, 180 kV, 250 kV, Cs and Co) with two different pure gases namely acetylene C2 H2 and carbon dioxide CO2. The different calibration factors were compared both for in-air and in-water phantom, the measurements were performed according to the international atomic energy agency (IAEA) recommendations. For ionization chamber the total absorbed dose can be derived from the charge produced within its cavity employing a number of physical parameters. To discuss the charge produced in the cavity several correction factors which are related to the operational characteristics of the chambers have to be introduced. Information on the operational characteristics of two TE neutron ionization chambers were studied as a function of the effects of the warm-up to 3 hours, polarity, stem scattering, ion recombination, leakage current. Six different caps 1, 2, 3, 4, 6 and 8 mm were used to investigate wall thickness effect. Also, gas flow rate up to 31 ml/min and the radial & axial uniformity were investigated. [A. I. Abd El-Hafez and M. Ezzat Evaluation of Correction Factors Applied in Photon Calibration of NIS TE Neutron Ionization Chambers Journal of American Science 2011;7(3):758-772]. (ISSN: 1545-1003). http://www.americanscience.org.
منابع مشابه
Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملDosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels
Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...
متن کاملMeasurements of output factors using different ionization chambers and build up caps
Background: The aim of this work was to study the output factors for Linac using different ionization chambers and build up caps. Materials and Methods: Output factors were measured for open square fields (3 × 3 cm to 40 × 40 cm) defined by collimator jaws for 6 and 15 MV photon beams from a Varian Clinac 2100C accelerator were measured. The measurements in air were performed using Com...
متن کاملSU-E-T-15: Small and Nonstandard Photon Field Dosimetry Characterization Using Monte Carlo Methods.
PURPOSE To quantify uncertainty reduction in small photon field dosimetry through characterization of ionization chambers and calibration conditions using detailed Monte Carlo methods benchmarked against NIST-traceable measurements. METHODS Phase space profiles were obtained using detailed EGSnrc Monte Carlo models for a Varian 6 MV photon linear accelerator, and a NIST-traceable cobalt-60 te...
متن کاملSome steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department
Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011