Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials.

نویسندگان

  • George C Cho
  • Winston W L Chee
چکیده

STATEMENT OF PROBLEM Impressions are made using high-viscosity putty vinyl polysiloxane impression materials in conjunction with disposable plastic stock trays. The impression materials have been shown to be dimensionally stable. However, it remains unclear if the disposable plastic stock trays are rigid enough to resist deformation thus yielding potentially unreliable results. PURPOSE This study evaluated the rigidity and ability to resist deformation of 6 commercially available disposable plastic stock trays and 1 metal stock tray when used in conjunction with a high-viscosity vinyl polysiloxane impression material. MATERIAL AND METHODS Ten impressions were made with 1 putty vinyl polysiloxane material (Reprosil Putty) using each of the 6 tested disposable plastic stock trays, Sani-Trays (perforated), Sani-Trays (nonperforated), COE Disposable Spacer Tray (perforated), COE Disposable Spacer Tray (nonperforated), Bosworth Tray-Aways (perforated), Track-it Trays (perforated), and 1 metal stock tray (nonperforated), Cadco Dental Products, as a control on a mandibular plastic model. The dimensions of the tray in cross section at the mandibular right first molar area were measured before, during, and after the impression procedures with an electronic digital caliper. The cross-arch dimensions of the tray were measured at similar intervals. One examiner made all measurements and each measurement was repeatable within +/-0.01 mm. A split plot repeated measures analysis of variance (ANOVA) was performed and 2-sided P -values were calculated (alpha=.05). RESULTS The results indicated that the disposable plastic trays tested were not sufficiently rigid to resist deformation when used with very high-viscosity putty material. Metal stock trays showed significantly less change in cross-arch dimension than plastic trays (F(1.68)=11.25, P =.001). Metal stock trays also showed significantly less change in cross-sectional arch dimension than plastic trays (F(1.68)=15.15, P<.001). CONCLUSION When disposable plastic stock trays were tested in conjunction with very high-viscosity impression materials there was distortion of the tray both across the arch and in cross section.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo Study of the Accuracy of Dual-arch Impressions.

BACKGROUND This study evaluated in vivo the accuracy of metal (Smart®) and plastic (Triple Tray®) dual-arch trays used with vinyl polysiloxane (Flexitime®), in the putty/wash viscosity, as well as polyether (Impregum Soft®) in the regular viscosity. MATERIALS AND METHODS In one patient, an implant-level transfer was screwed on an implant in the mandibular right first molar, serving as a patte...

متن کامل

The influence of handling on the elasticity of addition silicone putties.

The handling of vinyl polysiloxane (addition silicone) impression putties with latex gloves is said to interfere with the setting of these impression materials. The aim of this study is to evaluate the effect of handling techniques on the setting of vinyl polysiloxane impression putties using several types of gloves. The setting of these materials was evaluated by means of an elasticimeter. Fou...

متن کامل

Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays.

STATEMENT OF PROBLEM Success rates for making fixed prosthodontic impressions based on material and tray selection are not known. PURPOSE The purpose of this clinical study was to compare first impression success rates for 2 types of impression material and 2 impression tray systems. MATERIAL AND METHODS Dual-viscosity impressions were made with a vinyl polysiloxane (VPS) (Aquasil Ultra Mon...

متن کامل

Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.

BACKGROUND Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using thre...

متن کامل

Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring

This study evaluated the accuracy of gypsum casts after different impression techniques and double pouring. Ten patients were selected and for each one it was obtained 5 partial putty/wash impressions with vinyl polysiloxane (VPS) material from teeth #13 to #16 with partial metal stock trays. The following techniques were performed: (1) one-step; two-step relief with: (2) PVC film; (3) slow-spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 92 4  شماره 

صفحات  -

تاریخ انتشار 2004