A trabecular metal tibial component in total knee replacement in patients younger than 60 years: a two-year radiostereophotogrammetric analysis.
نویسندگان
چکیده
We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial component and 19 (mean 53 years, 44 to 59, 21 knees) a cemented NexGen Option cruciate-retaining modular tibial component. All the trabecular metal components migrated during the initial three months and then stabilised. The exception was external rotation, which did not stabilise until 12 months. Unlike conventional metal-backed implants which displayed a tilting migration comprising subsidence and lift-off from the tibial tray, most of the trabecular metal components showed subsidence only, probably due to the elasticity of the implant. This pattern of subsidence is regarded as being beneficial for uncemented fixation.
منابع مشابه
Total knee arthroplasty Aspects on improved fixation in the younger patient Av
Mobile bearings do not improve fixation in cemented total knee arthroplasty. Trabecular metal tibial component in patients younger than 60 years. A prospective RSA study. Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 years. A randomized RSA study. Submitted 2008.
متن کاملTrabecular metal tibial knee component still stable at 10 years
Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years. In this study, we compared the clinical and RSA ...
متن کاملTrabecular metal tibia still stable at 5 years
BACKGROUND AND PURPOSE Clinical results of total knee replacement (TKR) are inferior in younger patients, mainly due to aseptic loosening. Coating of components with trabecular metal (TM) is a new way of enhancing fixation to bone. We have previously reported stabilization of TM tibial components at 2 years. We now report the 5-year follow-up of these patients, including RSA of their TM tibial ...
متن کاملBetter Survival of Total Knee Replacement in Patients Older Than 70 Years: A Prospective Study with 8 To 12 Years Follow-Up
Background: Modern knee designs have popularized its use in younger patients due to its better performance. There remains uncertainty whether higher demands of these patients can affect implant survivorship. Purpose: To assess whether modern knee designs have provided similar results in patients younger than 70 years versus older patients. Methods: We included 203 consecutive patients (236 ...
متن کاملShould we reconsider all-polyethylene tibial implants in total knee replacement?
The role of modular tibial implants in total knee replacement is not fully defined. We performed a prospective randomised controlled clinical trial using radiostereophotogrammetric analysis to compare the performance of an all-polyethylene tibia with a metal-backed cruciate-retaining condylar design, PFC-Sigma total knee replacement for up to 24 months. There were 51 patients who were randomise...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 12 شماره
صفحات -
تاریخ انتشار 2008