Reaction kinetics and validity of BOD test for domestic wastewater released in marine ecosystems.

نویسندگان

  • Shivani S Dhage
  • Amita A Dalvi
  • Damodar V Prabhu
چکیده

With urbanization of coastal cities, marine pollution is becoming a severe problem. The rates of biodegradation, decomposition, and ratification of pollutants get slowed down due to salinity. The higher temperatures prevalent in tropical regions significantly affect reaction rates. Multiple factors influence the rate of biodegradation, making the process complex. Hence, prediction and evaluation of the assimilative capacity of the marine environment due to wastewater discharges is becoming a difficult task. Biochemical oxygen demand (BOD) is a wet oxidation process, which follows first-order kinetics. The values of kinetic rate constants are expected to differ with varying salinities and temperatures. Research is carried out using glucose-glutamic acid and domestic wastewater to evaluate the impact of salinity on biodegradation of carbonaceous waste at 20°C and 27°C. The findings confirm the hypothesis of slow biodegradation of carbonaceous organic matter in marine waters. An inverse relationship between rate of biodegradation and salinity was observed. BOD exertion at 20°C (5 days) and 27°C (3 days) for the marine environment is comparable at selected salinities thereby confirming the validity of BOD test of shorter duration at elevated temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of sand-bed filtration on the oxygen demand characteristics of wastewaters from domestic, institutional and industrial sources

Wastewaters from three different sources, private residence (domestic), medical clinic (institutional) and polymer industry (industrial) were characterised for their pollution potentials. The results of analysis show pH of 7.6, 6.5 and 6.3 for domestic, institutional and industrial wastewater, respectively. The DO, BOD and COD was found to be 4.01, 66 and 114 mg/l for the domestic wastewater, 3...

متن کامل

Comparison Study of Different BOD Tests in the Determination of BOD7 Evaluated in a Model Domestic Sewage

The aim of this research was to study the suitability of a manometric respirometric test (OECD 301F) for the determination of biological oxygen demand (BOD) in domestic wastewater. This was done by comparing four different BOD tests (a manometric respirometric test, oxygen sensor determination, iodometric titration, and UV absorption measurement) and by evaluating the BOD(7) value after a short...

متن کامل

Treatability Evaluation of Municipal Wastewater and Anaerobically-Treated Industrial Effluent in a Rotating Biological Contactor

Performance of a rotating biological contactor (RBC) in treating municipal wastewater from primary sedimentation basin and anaerobically treated industrial effluent from an upflow anaerobic sludge blanket (UASB) reactor was investigated. The 280-L six-stage RBC pilot was operated at different organic loading rates and biodisc speeds. The overall removal efficiencies of soluble BOD decreased wit...

متن کامل

Development and Long-Term Stability of a Novel Microbial Fuel Cell BOD Sensor with MnO2 Catalyst

A novel microbial fuel cell (MFC)-based biosensor was designed for continuous monitoring of biochemical oxygen demand (BOD) in real wastewater. To lower the material cost, manganese dioxide (MnO₂) was tested as an innovative cathode catalyst for oxygen reduction in a single chamber air-cathode MFC, and two different crystalline structures obtained during synthesis of MnO₂ (namely β- and γ-MnO₂)...

متن کامل

Dairy wastewater treatment plant in removal of organic pollution: a case study in Sanandaj, Iran

Background: Wastewater produced by a dairy in Sanandaj is a major source of environmental pollution threatening the city. The dairy uses activated sludge treatment to remove organic pollution from the wastewater. The present study evaluated the performance of this process and its compliance with national requirements for chemical oxygen demand (COD), biochemical oxygen demand (BOD), and total s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental monitoring and assessment

دوره 184 9  شماره 

صفحات  -

تاریخ انتشار 2012