Upgrade of far-infrared laser-based Faraday rotation measurement on MST.
نویسندگان
چکیده
Recently, the far-infrared (FIR) laser (λ(0)=432 μm) Faraday rotation measurement system on MST has been upgraded. The dc flowing-gas discharge CO(2) pump laser is replaced by a rf-excited, sealed CO(2) laser at 9.27 μm (GEM select 100, Coherent Inc., Santa Clara, CA), which is subdivided equally into three parts to simultaneously pump three FIR cavities. The total infrared pump power is approximately 80 W on the 9R(20) line required to pump the formic acid molecule. Each FIR cavity produces ∼12 mW, sufficient for 11 simultaneous chord interferometry-polarimetry operations. Three key issues [(1) conservation of circularly polarized wave, (2) colinearity of two probe waves, and (3) stability of intermediate frequencies between lasers] affecting the Faraday rotation measurement have been resolved experimentally.
منابع مشابه
Fizeau interferometer for measurement of plasma electron current
A high-resolution, vertically viewing far-infrared polarimeter-interferometer system is currently used on the Madison symmetric torus (MST) reversed-field pinch (RFP) to measure the plasma electron density and toroidal current density via Faraday rotation. In this article, we propose a scheme to measure the well-known Fizeau effect, whereby through modest modification of the existing apparatus,...
متن کاملLaser Faraday rotation measurement of current density fluctuations and electromagnetic torque (invited)
Far-infrared laser polarimetry with time response up to ,1 ms and spatial resolution ,8 cm has been successfully implemented on the Madison Symmetric Torus reversed-field pinch. Internal magnetic field and current density fluctuations are nonperturbatively measured. This is accomplished by taking parallel polarimetry chords which measure the line-integrated magnetic field fluctuations via Farad...
متن کاملSimultaneous density and magnetic field fluctuation measurements by far-infrared interferometry and polarimetry in MST.
Fluctuations are expected to play an important role in anomalous particle, momentum, and energy transport for magnetic confinement devices. Magnetic and density fluctuations are simultaneously measured using a high-speed laser-based Faraday rotation-interferometry system with a bandwidth of 500 kHz and 8 cm chord spacing. Density fluctuation and magnetic fluctuation profiles are obtained by usi...
متن کاملA Stark-tuned laser application for interferometry and polarimetry on the National Spherical Torus Experiment
Interferometer/polarimeter systems based on far infrared lasers have suffered from lack of frequency modulation techniques that can allow higher intermediate frequency ~IF! frequency for a fast time resolution together with stable operation including low frequency drift. This is mainly due to the intrinsic narrow gain profile of the lasers. It is known that the Stark effect can broaden the lase...
متن کاملFaraday-effect polarimeter-interferometer system for current density measurement on EAST.
A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 81 10 شماره
صفحات -
تاریخ انتشار 2010