Ocular aberrations with ray tracing and Shack-Hartmann wave-front sensors: does polarization play a role?

نویسندگان

  • Susana Marcos
  • Luis Diaz-Santana
  • Lourdes Llorente
  • Chris Dainty
چکیده

Ocular aberrations were measured in 71 eyes by using two reflectometric aberrometers, employing laser ray tracing (LRT) (60 eyes) and a Shack-Hartmann wave-front sensor (S-H) (11 eyes). In both techniques a point source is imaged on the retina (through different pupil positions in the LRT or a single position in the S-H). The aberrations are estimated by measuring the deviations of the retinal spot from the reference as the pupil is sampled (in LRT) or the deviations of a wave front as it emerges from the eye by means of a lenslet array (in the S-H). In this paper we studied the effect of different polarization configurations in the aberration measurements, including linearly polarized light and circularly polarized light in the illuminating channel and sampling light in the crossed or parallel orientations. In addition, completely depolarized light in the imaging channel was obtained from retinal lipofuscin autofluorescence. The intensity distribution of the retinal spots as a function of entry (for LRT) or exit pupil (for S-H) depends on the polarization configuration. These intensity patterns show bright corners and a dark area at the pupil center for crossed polarization, an approximately Gaussian distribution for parallel polarization and a homogeneous distribution for the autofluorescence case. However, the measured aberrations are independent of the polarization states. These results indicate that the differences in retardation across the pupil imposed by corneal birefringence do not produce significant phase delays compared with those produced by aberrations, at least within the accuracy of these techniques. In addition, differences in the recorded aerial images due to changes in polarization do not affect the aberration measurements in these reflectometric aberrometers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye.

A comparison and validation study of Laser Ray Tracing (LRT) and Hartmann-Shack wave-front-sensor (to be referred to as H-S) methods was carried out on both artificial and human eyes. The aim of this work was double. First, we wanted to verify experimentally the equivalence of single- and double-pass measurements for both H-S and LRT. This interest is due to the impossibility of making single-p...

متن کامل

Aberrations of the human eye in visible and near infrared illumination.

PURPOSE In most current aberrometers, near infrared light is used to measure ocular aberrations, whereas in some applications, optical aberration data in the visible range are required. We compared optical aberration measurements using infrared (787 nm) and visible light (543 nm) in a heterogeneous group of subjects to assess whether aberrations are similar in both wavelengths and to estimate e...

متن کامل

Comparing laser ray tracing, the spatially resolved refractometer, and the Hartmann-Shack sensor to measure the ocular wave aberration.

PURPOSE To compare quantitatively three techniques to measure the optical aberrations of the human eye: laser ray tracing (LRT), the Hartmann-Shack wavefront sensor (H-S), and the spatially resolved refractometer (SRR). LRT and H-S are objective imaging techniques, whereas SRR is psychophysical. METHODS Wave aberrations were measured in two normal subjects with all three techniques implemente...

متن کامل

Evaluation of the comparability and repeatability of four wavefront aberrometers.

PURPOSE To compare total ocular aberrations and corneal aberrations identified with four different aberrometers and to determine the repeatability and interobserver variability. METHODS In this prospective comparative study, 23 healthy subjects underwent bilateral examination with four aberrometers: the Irx3 (Hartmann-Shack; Imagine Eyes, Orsay, France), Keratron (Hartmann-Shack; Optikon, Rom...

متن کامل

Ocular wave-front aberration statistics in a normal young population

Monochromatic ocular aberrations in 108 eyes of a normal young population (n=59) were studied. The wave-front aberration were obtained under natural conditions using a near-infrared Shack-Hartmann wave-front sensor. For this population and a 5 mm pupil, more than 99% of the root-mean square wave-front error is contained in the first four orders of a Zernike expansion and about 91% corresponds o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 2002