Evaluation of cardiac valvular regurgitant lesions by cardiac MRI sequences: comparison of a four valve semi-quantitative vs. quantitative approach
نویسندگان
چکیده
BACKGROUND AND AIM OF THE STUDY Cardiac magnetic resonance (CMR) imaging generally allows a more accurate and valid quantification of cardiac function, mass and regurgitant volumes than echocardiography. Although recent technological advancements in CMR have made the evaluation of cardiac valves more reliable, no studies have yet been conducted to compare semi-quantitative grading (SQG) using CMR steady-state free precession (SSFP) sequences with quantitative grading (QG) based on stroke volumes and phase-velocity mapping (PVM). It is proposed that the SQG of cardiac valvular regurgitations based on CMR SSFP sequences is feasible, and highly correlative with standard CMR QG methods. METHODS CMR data obtained between January 2007 and December 2011 was evaluated prospectively for valvular regurgitant lesions. Patients were included if they had right and left ventricular volumetrics based on CMR SSFP sequences and PVM across the aortic and pulmonic valves with reported regurgitant volumes and fractions. Patients were excluded if they had prosthetic valves, cardiac arrhythmias and intra-cardiac shunts. Regurgitant lesions were semi-quantitatively (visually) graded on a standard scale of 0 to 4 (trace, mild, moderate, moderate to severe, and severe) and compared with quantitative regurgitant fractions. Correlations were evaluated by Spearman's rho formula, and kappa for intra- and inter-observer variabilities were obtained on 30% of the study sample. RESULTS A total of 97 patients (58 males, 39 females; average age 55 +/- 18 years) representing 134 valvular regurgitations [mitral (MR), aortic (AR), tricuspid (TR), and pulmonary (PR)] were analyzed by semiquantitative and quantitative methods. The regurgitant lesions included 44 mitral, 50 aortic, 29 tricuspid, and 11 pulmonary. The correlation between SQR versus QG yielded the following results: 0.67, p < 0.001 (MR, r = 0.66, p < 0.001; AR, r = 0.68, p < 0.002; TR, r = 0.68, p = 0.001; PR, r = 0.70, p = 0.017). The results for QG versus SQG accounting for clinically significant differences of +/- 1 grade for the group were as follows: 0.95, p < 0.001 (MR, r = 0.91, p < 0.001; AR, r = 0.96, p < 0.001; TR, r = 0.99, p < 0.001; PR, r = 0.93, p < 0.001). No discrepancy between surgical regurgitation was present (3+ versus 4+). Weighted kappa results were 0.67 and 0.61 for intra- and inter-observer variabilities. CONCLUSION The visual assessment of cardiac regurgitant lesions is reliable, accurate and reproducible when compared to formal quantitative analysis via CMR. This confirms a robust role for CMR in assessing regurgitant lesions, particularly for surgical decision-making. These results were applicable to patients in sinus rhythm at the time of scanning.
منابع مشابه
Noninvasive quantitation of valvular regurgitation by gated equilibrium radionuclide angiography.
R-wave synchronous equilbrium radionuclide angiography (RNA) is a noninvasive method that provides time-activity curve count information proportional to ventricular volumes and is used for relative volume comparisons within the left or right ventricle to derive the ejection fraction. Comparison of the ventricular count output between both ventricles may permit quantitation of the relative amoun...
متن کاملNormal Echocardiographic Findings in Healthy Pigeons
Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...
متن کاملClinical evaluation versus Doppler echocardiography in the quantitative assessment of valvular heart disease.
We tested the hypotheses that Doppler echocardiography has a higher accuracy than clinical evaluation in the detection of significant aortic and mitral valvular heart disease and that Doppler echocardiography is highly accurate as compared with cardiac catheterization for the assessment of valvular disease severity. Thus, cardiac catheterization for the assessment of valve lesion severity may b...
متن کاملAnalysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI
PURPOSE The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. METHODS left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-qua...
متن کاملEvaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients
Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -
تاریخ انتشار 2013