Peculiarities of the continuous glucose monitoring data stream and their impact on developing closed-loop control technology.

نویسندگان

  • Boris Kovatchev
  • William Clarke
چکیده

Therapeutic advances in type 1 diabetes (T1DM) are currently focused on developing a closed-loop control system using a continuous glucose monitor (CGM), subcutaneous insulin delivery, and a control algorithm. Because a CGM assesses blood glucose indirectly (and therefore often inaccurately), it limits the effectiveness of the controller. In order to improve the quality of CGM data, a series of analyses are suggested. These analyses evaluate and compensate for CGM errors, assess risks associated with glucose variability, predict glucose fluctuation, and forecast hypo- and hyperglycemia. These analyses are illustrated with data collected using the MiniMed CGMS® (Medtronic, Northridge, CA) and Freestyle Navigator(™) (Abbott Diabetes Care, Alameda, CA). It is important to remember that traditional statistics do not work with CGM data because consecutive CGM readings are highly interdependent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous glucose monitoring considerations for the development of a closed-loop artificial pancreas system.

BACKGROUND Commercialization of a closed-loop artificial pancreas system that employs continuous subcutaneous insulin infusion and interstitial fluid glucose sensing has been encumbered by state-of-the-art technology. Continuous glucose monitoring (CGM) devices with improved accuracy could significantly advance development efforts. However, the current accuracy of CGM devices might be adequate ...

متن کامل

Impact of real-time continuous glucose monitoring on children and their families.

Real-time continuous glucose monitoring (CGM) devices have great potential to improve glycemic management in children and adolescents with diabetes and other disorders of glucose regulation. These devices can be used as either adjuncts or replacements for traditional meters because they have additional features such as blood sugar alarms and glucose-trend information. These features allow for d...

متن کامل

Continuous glucose monitoring awaits its "killer app".

Continuous glucose monitoring (CGM) could drive a paradigm shift in diabetes care, but realization of this promise awaits a complementary shift in the way CGM data is used. The most exciting use for CGM is as the input for automated, closed-loop glucose control. Although first generation CGM devices leave much room for improvement, closed-loop control does not have to wait. Algorithms should ta...

متن کامل

Dynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach

This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...

متن کامل

Continuous Performance Monitoring of a Closed-Loop Insulin Delivery System using Bayesian Surprise

The development of an artificial pancreas for the treatment of insulin-dependent diabetes is a big challenge for control theory. Many closed-loop algorithms have been widely evaluated for their ability to recreate, as closely as possible, glucose and insulin profiles observed in healthy individuals. Nevertheless, an artificial pancreas system also involves a critical necessity for supervision o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 2 1  شماره 

صفحات  -

تاریخ انتشار 2008