Quantification of absolute luminal diameter by computer-analyzed digital subtraction angiography: an assessment in human coronary arteries.

نویسندگان

  • M C Rosenberg
  • L W Klein
  • J B Agarwal
  • G Stets
  • G A Hermann
  • R H Helfant
چکیده

Determination of absolute lumen diameters has been shown to be useful in predicting the functional importance of a coronary stenosis. In this study, both single-plane and orthogonal biplane digital subtraction angiograms were obtained in human cadaver coronary arteries. A single absolute diameter was calculated at the site of greatest narrowing in 20 segments by two automated computerized algorithms. Minimum and maximum diameters at the site of the stenosis were measured from pathologic sections prepared after pressure fixation. Method 1, which determines the edges by means of the first derivative of the videodensity curve, derived absolute diameters that fell between the pathologic minimum and maximum in 10 of 20 segments. Method 2, which determines the edges by an average of the first and second derivatives of the videodensity change, derived absolute diameters that fell between the pathologic minimum and maximum diameters in 15 of 20 segments. Method 1 correlated well with the maximum pathologic diameter (r = .76) and less well with the minrmum pathologic diameter (r = .67). Method 2 correlated very well with the maximum pathologic diameter (r = .79) and also correlated well with the minimum pathologic diameter (r = .74). As would be expected, the computerized algorithms tended to overestimate the minimum pathologic diameter and to underestimate the maximum pathologic diameter. In six segments, two orthogonal views were analyzed; no further accuracy was discernible over single-plane determinations. Thus quantitative coronary angiography by digital subtraction angiography is sufficiently accurate to be of use in the measurement of the severity of a coronary stenosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mild carotid artery atherosclerosis: assessment by 3-dimensional time-of-flight magnetic resonance angiography, with reference to intravascular ultrasound imaging and contrast angiography.

BACKGROUND AND PURPOSE Our aim was to evaluate the usefulness of 3-dimensional time-of-flight magnetic resonance angiography (3-D TOF MRA) in detection and quantification of mild atherosclerotic changes of carotid arteries with reference to intravascular ultrasound (IVUS) and contrast angiography. METHODS TOF MRA at 1.5 T, IVUS, and selective digital subtraction angiography were performed on ...

متن کامل

Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference

OBJECTIVE We sought to evaluate the accuracy of quantitative three-dimensional (3D) CT angiography (CTA) for the assessment of coronary luminal stenosis using digital subtraction angiography (DSA) as the standard of reference. METHOD Twenty-three patients with 54 lesions were referred for CTA followed by DSA. The CTA scans were performed with 256-slice spiral CT. 3D CTA were reconstructed fro...

متن کامل

Cross-sectional area and volume compliance of porcine left coronary arteries.

We have determined the cross-sectional area (CSA) compliance of the first several generations of pig coronary arteries and the volume compliance of the coronary arterial tree (vessels >0.5 mm in diameter) using a videodensitometric technique. The coronary arteries of four KCl-arrested maximally vasodilated pig hearts were perfused with iodine and 3% Cab-O-Sil. Because Cab-O-Sil occludes small a...

متن کامل

Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve STEVEN

Conventional coronary angiography has significant limitations in quantifying the severity and functional significance of coronary stenoses. However, coronary reactive hyperemia is an excellent physiologic indicator of coronary reserve. Digital subtraction angiography offers the potential to analyze coronary blood flow dynamics quantitatively. Therefore we assessed the accuracy of digital angiog...

متن کامل

Diagnostic Methods Coronary Artery Disease

To study the relationship between the quantitatively assessed coronary artery dimensions and the regional coronary flow reserve as measured by digital subtraction cineangiography, we investigated 17 coronary arteries with a single discrete proximal stenosis and 12 normal coronary arteries before and after intracoronary administration of papaverine. Coronary flow reserve was found to be curvilin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 77 2  شماره 

صفحات  -

تاریخ انتشار 1988