Improved Semi-Automatic Basket Catheter Reconstruction from two X-Ray Views

نویسندگان

  • Xia Zhong
  • Matthias Hoffmann
  • Norbert Strobel
  • Andreas K. Maier
چکیده

Ablation guided by focal impulse and rotor mapping (FIRM) is an alternative treatment for atrial fibrillation in particular for persistent atrial fibrillation. To this end, a basket catheter comprising 64 electrodes is inserted into both the right atrium and left atrium under X-ray guidance to locate electric anomalies. The 3-D positions of the electrodes are needed to determine the ablation region. We propose a improved model-based method for 3-D reconstruction of this basket catheter based on two X-ray views. In our experiments, we found that the proposed approach outperformed our previous approach. The median error using the proposed method are 1.5mm for phantom data and 2.6mm for clinical data. We also introduced a novel error metric, the overlap rate between ground truth ablation region and reconstructed ablation region. The overall mean overlap rate under optimized viewing angle conditions is 84± 14% for phantom data and 72± 16% for clinical data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-Automatic Basket Catheter Reconstruction from Two X-Ray Views

Ablation guided by focal impulse and rotor mapping (FIRM) is a novel treatment option for atrial fibrillation, a frequent heart arrhythmia. This procedure is performed minimally invasively and at least partially under fluoroscopic guidance. It involves a basket catheter comprising 64 electrodes. The 3-D position of these electrodes is important during treatment. We propose a novel model-based m...

متن کامل

Semi-automatic Catheter Reconstruction from Two Views

We propose novel methods for (a) detection of a catheter in fluoroscopic images and (b) reconstruction of this catheter from two views. The novelty of (a) is a reduced user interaction and a higher accuracy. It requires only a single seed point on the catheter in the fluoroscopic image. Using this starting point, possible parts of the catheter are detected using a graph search. An evaluation of...

متن کامل

CathNets: Detection and Single-View Depth Prediction of Catheter Electrodes

Electrophysiology procedures are commonly carried out under guidance of C-arm fluoroscopy, but precise localization of the surgical instruments within the patients anatomy is done using expensive electro-anatomic mapping systems • Potential Alternative: Optical catheter detection, tracking & 3D reconstruction in fluoroscopic X-ray images • State of the Art: i) Gaussian blob detectors[3,4] for d...

متن کامل

Two-stage Semi-automatic Organ Segmentation Framework using Radial Basis Functions and Level Sets

The automatic segmentation of complex anatomical structures often fails due to low-contrast or missing edges, pathologic alterations, or high noise. As an alternative, we propose a novel two-stage semi-automatic algorithm that is able to segment complex structures like the liver shape with moderate user interaction. The first stage of our algorithm is the manual delineation of cross-sections of...

متن کامل

A Semi-Automatic Algorithm for Estimating Cobb Angle

Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016