A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria.

نویسندگان

  • Robert C Hendel
  • Manuel Cerqueira
  • Pamela S Douglas
  • Karen C Caruth
  • Joseph M Allen
  • Neil C Jensen
  • Wenqin Pan
  • Ralph Brindis
  • Michael Wolk
چکیده

OBJECTIVES The aim of this study was to assess the feasibility of evaluation for appropriate use of radionuclide myocardial perfusion imaging (MPI) in multiple clinical sites and to determine use patterns as well as identify areas of apparent inappropriate use. BACKGROUND Although cardiac imaging is highly valued for decision-making, the growth and expense related to these procedures has raised questions regarding overuse. The publication of appropriate use criteria (AUC), including those for MPI, were designed to provide guidance in the rational use of testing. However, limited data regarding the implementation and evaluation of AUC are available. METHODS Six diverse clinical sites enrolled consecutive patients undergoing MPI, collecting point-of-service data entered into an online form. An automated algorithm assigned a specific indication from the AUC that was classified as appropriate, uncertain, or inappropriate. Site-specific feedback was later provided to each practice on ordering patterns. RESULTS Of the 6,351 patients enrolled, 93% were successfully assigned an appropriateness level. Inappropriate use of MPI was found in 14.4% of patients, with a range of 4% to 22% among practices. Women and younger patients were more likely to undergo inappropriate MPI. Asymptomatic, low-risk patients accounted for 44.5% of inappropriate testing. Elimination of the 5 most common inappropriate use indications would reduce overall imaging volume by 13.2%. Inappropriate use by physicians from within the practice performing imaging was not greater than physicians outside of the practice. Educational feedback might have resulted in reduced inappropriate test ordering in 1 site. CONCLUSIONS The tracking of appropriate use is feasible in clinical practice, with an automated system that can readily identify practice patterns and targets for educational and quality improvement initiatives. This approach might provide an alternative to utilization management.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

ASNC INFORMATION STATEMENT American Society of Nuclear Cardiology review of the ACCF/ASNC appropriateness criteria for single-photon emission computed tomagraphy myocardial perfusion imaging (SPECT MPI)

The American College of Cardiology Foundation (ACCF) and the American Society of Nuclear Cardiology (ASNC) have published criteria for the appropriate use of single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) with regard to a variety of clinical indications and scenarios. In determining the appropriate use of MPI for a given clinical indication, evidence-based...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

Applicability of appropriateness criteria for stress imaging: similarities and differences between stress echocardiography and single-photon emission computed tomography myocardial perfusion imaging criteria.

BACKGROUND Appropriateness criteria for stress imaging have been published to promote the effective use of stress nuclear scintigraphy and stress echocardiography. We sought to evaluate the application of the stress echocardiography appropriateness criteria to patients undergoing stress echocardiography in an academic medical center. METHODS AND RESULTS The stress echocardiography criteria we...

متن کامل

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2010