Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children
نویسندگان
چکیده
PURPOSE The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool children. METHODS A total of 133 healthy Korean preschool children were selected from 639 children (aged 3 to 6 years) who attended kindergarten in Seongnam, Gyeonggi province, Korea. Healthy children were defined according to the European Respiratory Society (ERS) criteria. All subjects underwent lung function tests using IOS. The relationships between IOS value (respiratory resistance (Rrs) and reactance (Xrs) at 5 and 10 Hz and resonance frequency (RF)) and age, height, and weight were analyzed by simple linear and multiple linear regression analyses. RESULTS The IOS success rate was 89.5%, yielding data on 119 children. Linear regression identified height as the best predictor of Rrs and Xrs. Using stepwise multiple linear regressions based on age, height, and weight, we determined regression equations and coefficients of determination (R(2)) for boys (Rrs(5)=1.934-0.009×Height, R(2)=12.1%; Xrs(5)=0.774+0.006×Height-0.002×Age, R(2)=20.2% and for girls (Rrs(5)=2.201-0.012×Height, R(2)=18.2%; Xrs(5)=-0.674+0.004×Height, R(2)=10.5%). CONCLUSION This study provides reference values for IOS measurements of normal Korean preschool children. These provide a basis for the diagnosis and monitoring of preschool children with a variety of respiratory diseases.
منابع مشابه
Reference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years.
The forced oscillation technique makes it possible to evaluate the mechanical properties of the respiratory system with a minimum of cooperation. The method is therefore especially useful in children. Impulse oscillometry (IOS) is a commercially available version of this technique. There is, as yet, limited information on reference values for IOS in children. The aim of this study was to extend...
متن کاملReference Equations for Impulse Oscillometry System Parameters in Healthy Brazilian Children and Adolescents.
BACKGROUND The impulse oscillometry system is a noninvasive method of evaluating respiratory mechanics that is being increasingly used in the pediatric population. To date, no reference equations have been developed for healthy Brazilian children and adolescents. The purpose of the study was to determine the reference equations for impulse oscillometry system parameters in healthy children and ...
متن کاملValues of impulse oscillometry in healthy mexican children and adolescents.
BACKGROUND The impulse oscillometry system (IOS) is increasingly used to evaluate lung function, but individual results must be compared with appropriate reference values. We aimed to obtain such reference values in Mexican children and adolescents. METHODS Healthy subjects were recruited from kindergartens and schools after their parents signed a consent letter. Respiratory system impedances...
متن کاملHeart failure impairs cerebral oxygenation during exercise in patients with COPD
provocation test for airway hyperresponsiveness: a phase 3 comparison study with hypertonic (4.5%) saline. Respir Res 2005; 6: 144. 4 Beydon N, Davis SD, Lombardi E, et al. An official American Thoracic Society/European Respiratory Society statement: pulmonary function testing in preschool children. Am J Respir Crit Care Med 2007; 175: 1304–1345. 5 Hall GL, Gangell C, Fukushima T, et al. Applic...
متن کاملRespiratory resistance by impulse oscillometry in healthy Iranian children aged 5-19 years.
The impulse oscillation system (IOS) measures respiratory impedance (Zrs) in terms of resistance (Rrs) and reactance (Xrs) at multiples of 5 Hz. These measurements can be used clinically to help diagnose and monitor respiratory disorders, independent of effort. There is, as yet, no information on reference values for IOS in Iranian adolescents.The predictive equation for resistance and impedanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 54 شماره
صفحات -
تاریخ انتشار 2011