Absolute accuracy and sensitivity analysis of OP-FTIR retrievals of CO2, CH4 and CO over concentrations representative of “clean air” and “polluted plumes”
نویسندگان
چکیده
When compared to established point-sampling methods, Open-Path Fourier Transform Infrared (OP-FTIR) spectroscopy can provide path-integrated concentrations of multiple gases simultaneously, in situ and near-continuously. The trace gas pathlength amounts can be retrieved from the measured IR spectra using a forward model coupled to a non-linear least squares fitting procedure, without requiring “background” spectral measurements unaffected by the gases of interest. However, few studies have investigated the accuracy of such retrievals for CO2, CH4 and CO, particularly across broad concentration ranges covering those characteristic of ambient to highly polluted air (e.g. from biomass burning or industrial plumes). Here we perform such an assessment using data collected by a field-portable FTIR spectrometer. The FTIR was positioned to view a fixed IR source placed at the other end of an IR-transparent cell filled with the gases of interest, whose target concentrations were varied by more than two orders of magnitude. Retrievals made using the model are complicated by absorption line pressure broadening, the effects of temperature on absorption band shape, and by convolution of the gas absorption lines and the instrument line shape (ILS). Despite this, with careful model parameterisation (i.e. the optimum wavenumber range, ILS, and assumed gas temperature and pressure for the retrieval), concentrations for all target gases were able to be retrieved to within 5%. Sensitivity to the aforementioned model inputs was also investigated. CO retrievals were shown to be Correspondence to: T. E. L. Smith ([email protected]) most sensitive to the ILS (a function of the assumed instrument field-of-view), which is due to the narrow nature of CO absorption lines and their consequent sensitivity to convolution with the ILS. Conversely, CO2 retrievals were most sensitive to assumed atmospheric parameters, particularly gas temperature. Our findings provide confidence that FTIRderived trace gas retrievals of CO2, CH4 and CO based on modeling can yield results with high accuracies, even over very large (many order of magnitude) concentration ranges that can prove difficult to retrieve via standard classical least squares (CLS) techniques. With the methods employed here, we suggest that errors in the retrieved trace gas concentrations should remain well below 10%, even with the uncertainties in atmospheric pressure and temperature that might arise when studying plumes in more difficult field situations (e.g. at uncertain altitudes or temperatures).
منابع مشابه
Airborne observations of trace gases over boreal Canada during BORTAS: campaign climatology, air mass analysis and enhancement ratios
In situ airborne measurements were made over eastern Canada in summer 2011 as part of the BORTAS experiment (Quantifying the impact of BOReal forest fires on Tropospheric oxidants over the Atlantic using Aircraft and Satellites). In this paper we present observations of greenhouse gases (CO2 and CH4) and other biomass burning tracers (CO, HCN and CH3CN), both climatologically and through case s...
متن کاملForecasting Air Pollution Concentrations in Iran, Using a Hybrid Model
The present study aims at developing a forecasting model to predict the next year’s air pollution concentrations in the atmosphere of Iran. In this regard, it proposes the use of ARIMA, SVR, and TSVR, as well as hybrid ARIMA-SVR and ARIMA-TSVR models, which combined the autoregressive part of the autoregressive integrated moving average (ARIMA) model with the support vector regression technique...
متن کاملShipborne solar absorption measurements of CO2, CH4, N2O and CO and comparison with SCIAMACHY WFM-DOAS retrievals
CO, CH4, N2O and CO2 were retrieved from high resolution solar absorption spectra obtained during a ship cruise from Capetown to Bremerhaven in January/February 2003 by Fourier Transform Infrared (FTIR) spectroscopy. Precisions of better than 0.5% for the column averaged volume mixing ratios (VMR) of CH4 and CO2 are achieved using of O2 as a reference gas. Shipborne FTIR-measurements of CO and ...
متن کاملLayered double hydroxides: Novel nanocatalysts for combustion of gaseous toluene from polluted air
The catalytic performance of Ni-Al, Mg-Al, and Co-Ni LDHs as novel nanocatalysts was evaluated in the oxidation of toluene. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR). The XRD and FTIR approved the structure and functional groups of the LDH, respectively. Also, the presence of cations with dif...
متن کاملCO2 Selective Carbon Tubular Membrane: The Effect of Stabilization Temperature on BTDA-TDI/MDI P84 co-polyimide
Membranes offer remarkable attributes such as possessing small equipment footprints, having high efficiency and are environmentally friendly, with carbon membranes progressively investigated for gas separation applications. In this study, carbon tubular membranes for CO2 separationare prepared via the dip-coating method with P84 co-polyimide as the carbon precursor. The prepared membranes were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011