Vitreous fluorophotometer data analysis by deconvolution.

نویسندگان

  • R T Smith
  • C J Koester
  • C J Campbell
چکیده

The measurement process in fluorophotometry inherently involves a loss of information due to the finite sampling volume of the instrument. Mathematically, the effect is expressed as a convolution of the actual fluorescein distribution with the spread function of the instrument. Scattering by the ocular media can increase the spread function over that due to the instrument alone. A method is proposed for deconvolution of vitreous fluorophotometry data. Simulation studies and analyses of patient data demonstrate recovery of information with this method, including enhancement of retinal peaks and resolution of detail in the posterior vitreous which was not apparent from the original scans.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of vitreous liquefaction on the intravitreal distribution of sodium fluorescein, fluorescein dextran, and fluorescent microparticles.

PURPOSE The effects of vitreous liquefaction in the elderly on the distribution of drugs from intravitreal injections, depots, or devices remains unclear. The purpose of the present study was to develop a liquefied vitreous model that simulates the aged condition, to enable the study of clinically relevant drug distribution. METHODS Dutch-belted rabbits were used to develop a study model usin...

متن کامل

Studies on the blood-retinal barrier after cryoretinopexy with vitreous fluorophotometry.

The extent of damage to the blood-retinal barrier, induced by cryoapplication on the sclera, was measured in adult pigmented rabbits by using a vitreous fluorophotometer. In eight isolated cryopexies. the intensity of each was equalized by stopping freez.ing exactly when a white spot started to appear in the fundus. and the blood-retinal barrier damage was repaired 7-10 days after the operation...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

An improved objective slit-lamp fluorophotometer using tungsten-halogen lamp excitation and synchronous detection.

A new design of fluorophotometer is described. The instrument can measure lower concentrations of fluorescent dye with greater accuracy than previous models.

متن کامل

An Investigation of Recent Deconvolution Methods for Well-Test Data Analysis

In this work, we present an investigation of recent deconvolution methods proposed by von Schroeter et al. (2002, 2004), Levitan (2005) and Levitan et al. (2006), and Ilk et al. (2006a, b). These works offer new solution methods to the long-standing deconvolution problem and make deconvolution a viable tool for well-test and production-data analysis. However, there exists no study presenting an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1986