Inter-study reproducibility of cardiovascular magnetic resonance tagging
نویسندگان
چکیده
BACKGROUND The aim of this study is to determine the test-retest reliability of the measurement of regional myocardial function by cardiovascular magnetic resonance (CMR) tagging using spatial modulation of magnetization. METHODS Twenty-five participants underwent CMR tagging twice over 12 ± 7 days. To assess the role of slice orientation on strain measurement, two healthy volunteers had a first exam, followed by image acquisition repeated with slices rotated ±15 degrees out of true short axis, followed by a second exam in the true short axis plane. To assess the role of slice location, two healthy volunteers had whole heart tagging. The harmonic phase (HARP) method was used to analyze the tagged images. Peak midwall circumferential strain (Ecc), radial strain (Err), Lambda 1, Lambda 2, and Angle α were determined in basal, mid and apical slices. LV torsion, systolic and early diastolic circumferential strain and torsion rates were also determined. RESULTS LV Ecc and torsion had excellent intra-, interobserver, and inter-study intra-class correlation coefficients (ICC range, 0.7 to 0.9). Err, Lambda 1, Lambda 2 and angle had excellent intra- and interobserver ICC than inter-study ICC. Angle had least inter-study reproducibility. Torsion rates had superior intra-, interobserver, and inter-study reproducibility to strain rates. The measurements of LV Ecc were comparable in all three slices with different short axis orientations (standard deviation of mean Ecc was 0.09, 0.18 and 0.16 at basal, mid and apical slices, respectively). The mean difference in LV Ecc between slices was more pronounced in most of the basal slices compared to the rest of the heart. CONCLUSIONS Intraobserver and interobserver reproducibility of all strain and torsion parameters was excellent. Inter-study reproducibility of CMR tagging by SPAMM varied between different parameters as described in the results above and was superior for Ecc and LV torsion. The variation in LV Ecc measurement due to altered slice orientation is negligible compared to the variation due to slice location. TRIAL REGISTRATION This trial is registered as NCT00005487 at National Heart, Lung and Blood institute.
منابع مشابه
Inter-study reproducibility of circumferential strain and strain rates at 1.5T and 3T: a comparison of tagging and feature tracking
Background Feature Tracking (FT) is a relatively new technique for measuring strain on cardiac magnetic resonance imaging (CMR), that has been shown to have reasonable interstudy reproducibility (Coefficient of variation (CoV) ~20%) in healthy volunteers. The inter-study reproducibility of FT has not yet been reported in any patient groups, nor compared to that of MRI tagging. We sought to dete...
متن کاملGlobal and regional left ventricular myocardial deformation measures by magnetic resonance feature tracking in healthy volunteers: comparison with tagging and relevance of gender
BACKGROUND Feature tracking software offers measurements of myocardial strain, velocities and displacement from cine cardiovascular magnetic resonance (CMR) images. We used it to record deformation parameters in healthy adults and compared values to those obtained by tagging. METHODS We used TomTec 2D Cardiac Performance Analysis software to derive global, regional and segmental myocardial de...
متن کاملAccelerated tagging for the assessment of left ventricular myocardial contraction under physical stress.
A TFEPI-CSPAMM sequence is introduced, which is optimized with respect to acquisition speed and image quality. The sequence is used in a stress study, where a short breath-hold duration is crucial, and tested for reproducibility of deformation parameters extracted by HARP for repeated measurements.
متن کاملQuantification of atrial dynamics using cardiovascular magnetic resonance: inter-study reproducibility
BACKGROUND Cardiovascular magnetic resonance (CMR) offers quantification of phasic atrial functions based on volumetric assessment and more recently, on CMR feature tracking (CMR-FT) quantitative strain and strain rate (SR) deformation imaging. Inter-study reproducibility is a key requirement for longitudinal studies but has not been defined for CMR-based quantification of left atrial (LA) and ...
متن کاملIntra- and inter-exam reproducibility of left ventricular twist measurements using Fourier analysis of STimulated Echoes (FAST)
Background Assessing the reproducibility of new quantitative magnetic resonance imaging (MRI) biomarkers is an important part of validation [1-3]. Fourier Analysis of STimulated Echoes (FAST) [4] is a new MRI tissue tagging method that has recently been shown to compare favorably to conventional estimates of left ventricular (LV) twist from cardiac tagged images, but with significantly reduced ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -