Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home

نویسندگان

  • H. Blauw
  • A. C. van Bon
  • R. Koops
  • J. H. DeVries
چکیده

AIMS To assess the performance and safety of an integrated bihormonal artificial pancreas system consisting of one wearable device and two wireless glucose sensor transmitters during short-term daily use at home. METHODS Adult patients with type 1 diabetes using an insulin pump were invited to enrol in this randomized crossover study. Treatment with the artificial pancreas started with a day and night in the clinical research centre, followed by 3 days at home. The control period consisted of 4 days of insulin pump therapy at home with blinded continuous glucose monitoring for data collection. Days 2-4 were predefined as the analysis period, with median glucose as the primary outcome. RESULTS A total of 10 patients completed the study. The median [interquartile range (IQR)] glucose level was similar for the two treatments [7.3 (7.0-7.6) mmol/l for the artificial pancreas vs. 7.7 (7.0-9.0) mmol/l for the control; p = 0.123]. The median (IQR) percentage of time spent in euglycaemia (3.9-10 mmol/l) was longer during use of the artificial pancreas [84.7 (82.2-87.8)% for the artificial pancreas vs. 68.5 (57.9-83.6)% for the control; p = 0.007]. Time in hypoglycaemia was 1.3 (0.2-3.2)% for the artificial pancreas and 2.4 (0.4-10.3)% for the control treatment (p = 0.139). Separate analysis of daytime and night-time showed that the improvements were mainly achieved during the night. CONCLUSIONS The results of this pilot study suggest that our integrated artificial pancreas provides better glucose control than insulin pump therapy in patients with type 1 diabetes at home and that the treatment is safe.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematically In Silico Comparison of Unihormonal and Bihormonal Artificial Pancreas Systems

Automated closed-loop control of blood glucose concentration is a daily challenge for type 1 diabetes mellitus, where insulin and glucagon are two critical hormones for glucose regulation. According to whether glucagon is included, all artificial pancreas (AP) systems can be divided into two types: unihormonal AP (infuse only insulin) and bihormonal AP (infuse both insulin and glucagon). Even t...

متن کامل

The artificial pancreas: current status and future prospects in the management of diabetes.

Recent advances in insulins, insulin pumps, continuous glucose-monitoring systems, and control algorithms have resulted in an acceleration of progress in the development of artificial pancreas devices. This review discusses progress in the development of external systems that are based on subcutaneous drug delivery and subcutaneous continuous glucose monitoring. There are two major system-level...

متن کامل

Outpatient glycemic control with a bionic pancreas in type 1 diabetes.

BACKGROUND The safety and effectiveness of automated glycemic management have not been tested in multiday studies under unrestricted outpatient conditions. METHODS In two random-order, crossover studies with similar but distinct designs, we compared glycemic control with a wearable, bihormonal, automated, "bionic" pancreas (bionic-pancreas period) with glycemic control with an insulin pump (c...

متن کامل

Intelligent blood glucose control in diabetic patients: design and simulation of an artificial pancreas

Background: Diabetes mellitus (DM) is a common chronic disease with diverse complications. About 10% of the earth's population suffer from this disease. For smart control of the blood glucose in DM patients, an artificial pancreas was designed and simulated by a predictive sliding mode controller considering the time delay of insulin effect. Method: In this method, one of the time-delay glucos...

متن کامل

Progress of artificial pancreas devices towards clinical use: the first outpatient studies.

PURPOSE OF REVIEW This article describes recent progress in the automated control of glycemia in type 1 diabetes with artificial pancreas devices that combine continuous glucose monitoring with automated decision-making and insulin delivery. RECENT FINDINGS After a gestation period of closely supervised feasibility studies in research centers, the last 2 years have seen publication of studies...

متن کامل