Testicular shielding in penile brachytherapy

نویسندگان

  • Arpita Bindal
  • Umesh Mahantshetty
  • Chandrashekhar M. Tambe
  • Yogesh Ghadi
  • Vedang Murthy
  • Shyam Kishore Shrivastava
چکیده

PURPOSE Penile cancer, although rare, is one of the common genitourinary cancers in India affecting mostly aged uncircumcised males. For patients presenting with small superficial lesions < 3 cm restricted to glans, surgery, radical external radiation or brachytherapy may be offered, the latter being preferred as it allows organ and function preservation. In patients receiving brachytherapy, testicular morbidity is not commonly addressed. With an aim to minimize and document the doses to testis after adequate shielding during radical interstitial brachytherapy for penile cancers, we undertook this study in 2 patients undergoing brachytherapy and forms the basis of this report. MATERIAL AND METHODS Two patients with early stage penile cancer limited to the glans were treated with radical high-dose-rate (HDR) brachytherapy using interstitial implant. A total of 7-8 tubes were implanted in two planes, parallel to the penile shaft. A total dose of 44-48 Gy (55-60 Gy EQD2 doses with α/β = 10) was delivered in 11-12 fractions of 4 Gy each delivered twice daily. Lead sheets adding to 11 mm (4-5 half value layer) were interposed between the penile shaft and scrotum. The testicular dose was measured using thermoluminescent dosimeters. For each patient, dosimetry was done for 3 fractions and mean calculated. RESULTS The cumulative testicular dose to left and right testis was 31.68 cGy and 42.79 cGy for patient A, and 21.96 cGy and 23.28 cGy for patient B. For the same patients, the mean cumulative dose measured at the posterior aspect of penile shaft was 722.15 cGy and 807.72 cGy, amounting to 16.4% and 16.8% of the prescribed dose. Hence, the application of lead shield 11 mm thick reduced testicular dose from 722-808 cGy to 21.96-42.57 cGy, an "absolute reduction" of 95.99 ± 1.5%. CONCLUSIONS With the use of a simple lead shield as described, we were able to effectively reduce testicular dose from "spermicidal" range to "oligospermic" range with possible reversibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of central shielding in the dose reporting for cervical cancer in EQD2 era

PURPOSE To evaluate the cumulative dose at point A for three and four centimeters central shielding. MATERIAL AND METHODS The plans of external beam radiotherapy plus conventional intracavitary brachytherapy were performed. Three or four centimeters central shieldings (after 44 Gy) were applied to the standard whole pelvis irradiation. Additional intracavitary brachytherapy 4 × 7 Gy at point ...

متن کامل

Evaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code

Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a sing...

متن کامل

Evaluation of sexual functions and sexual behaviors after penile brachytherapy in men treated for penile carcinoma

PURPOSE To assess sexual functions and behaviors of men treated by penile brachytherapy for a cancer of the penis. MATERIALS AND METHODS Thirty eight men (19 patients treated by penile brachytherapy for a cancer of the penis and 19 age paired-matched controls) participated in a survey about sexuality. The mean age of patients and controls were 73.2 +/- 11.7 and 70.0 +/- 10.5 years, respective...

متن کامل

Penile cancer brachytherapy HDR mould technique used at the Holycross Cancer Center

The aim of this pictorial essay is to present the mould based HDR brachytherapy technique used at the Holycross Cancer Center for penile cancer patients. We use images to describe this method step by step.

متن کامل

Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015