Electrical restitution in the endocardium of the intact human right ventricle.

نویسندگان

  • J M Morgan
  • D Cunningham
  • E Rowland
چکیده

OBJECTIVE To characterise electrical restitution in the intact human heart. PATIENTS AND METHODS A series of monophasic action potential electrical restitution curves were constructed from a single right ventricular endocardial site in eight patients (three men) without structural heart disease aged 52-68 (mean 55 years). A combination pacing/monophasic action potential electrode was used to pace and record monophasic action potentials at drive cycle lengths of from 350 ms to 1500 ms. Ventricular extrastimuli were delivered at 20 cycle intervals and decreased from the longest coupling interval attainable without escape beats. RESULTS Restitution curves shifted downward and towards the left; steady state action potential duration shifted from the restitution plateau and descended the curve, the amount of shift being linearly related to drive cycle length in two patients in whom the relation could be assessed; the amount of monophasic action potential shortening was a function of the degree of prematurity and that relation was unaffected by drive rate; the magnitude of restitution and the time constant of the restitution curve were not changed significantly by altered drive cycle length. CONCLUSION In the intact heart in vivo, electrical restitution (of the monophasic action potential) has similar characteristics to those (of the transmembrane action potential) in cellular preparations in vitro. Thus the alteration of action potential plateau currents by instantaneous rate change or drug effects, which can be directly observed by techniques available to the cellular electrophysiologist, may be indirectly assessed in vivo by characterisation of the effect of these on electrical restitution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Global endocardial electrical restitution in human right and left ventricles determined by noncontact mapping.

OBJECTIVES This study was aimed at evaluating global characteristics of electrical restitution in the human ventricle using noncontact mapping. BACKGROUND Steep action potential restitution (slope >1) and conduction velocity (CV) restitution have been linked with propensity to ventricular fibrillation, but clinical measurement of global electrical restitution had not been feasible. METHODS ...

متن کامل

Translational Physiology Steeper restitution slopes across right ventricular endocardium in patients with cardiomyopathy at high risk of ventricular arrhythmias

Selvaraj RJ, Picton P, Nanthakumar K, Chauhan VS. Steeper restitution slopes across right ventricular endocardium in patients with cardiomyopathy at high risk of ventricular arrhythmias. Am J Physiol Heart Circ Physiol 292: H1262–H1268, 2007. First published November 10, 2006; doi:10.1152/ajpheart.00913.2006.—Steep action potential duration (APD) restitution slopes ( 1) and spatial APD restitut...

متن کامل

Ventricular stimulus site influences dynamic dispersion of repolarization in the intact human heart

The spatial variation in restitution properties in relation to varying stimulus site is poorly defined. This study aimed to investigate the effect of varying stimulus site on apicobasal and transmural activation time (AT), action potential duration (APD) and repolarization time (RT) during restitution studies in the intact human heart. Ten patients with structurally normal hearts, undergoing cl...

متن کامل

Na+ channel distribution and electrophysiological heterogeneities in guinea pig ventricular wall.

We sought to explore the distribution pattern of Na(+) channels across ventricular wall, and to determine its functional correlates, in the guinea pig heart. Voltage-dependent Na(+) channel (Na(v)) protein expression levels were measured in transmural samples of ventricular tissue by Western blotting. Isolated, perfused heart preparations were used to record monophasic action potentials and vol...

متن کامل

Catheter recording and validation of left bundle-branch potentials in intact dogs.

The left bundle-branch potential (LB), as well as His bundle (H) and atrioventricular nodal (N) potentials, were recorded in intact dogs by using a tripolar electrode catheter positioned in the left ventricle. Simultaneous recordings of H and right bundlebranch (RB) activity from the right endocardial surface were also made. The LB potential was less rapid than the RB potential, but both occurr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 1992