High-Sensitivity and High-Resolution SPECT/CT Systems Provide Substantial Dose Reduction Without Compromising Quantitative Precision for Assessment of Myocardial Perfusion and Function.

نویسندگان

  • Richard J Palyo
  • Albert J Sinusas
  • Yi-Hwa Liu
چکیده

UNLABELLED There is increasing concern about radiation exposure from myocardial perfusion SPECT (MPS). γ-cameras with solid-state cadmium-zinc-telluride (CZT) detectors have better count sensitivity and spatial resolution than conventional sodium iodine detectors, allowing for significant reductions in radiotracer dose or acquisition time. This study aimed to demonstrate the capability of a hybrid CZT SPECT/64-slice CT system for dose reduction and to determine the maximal reduction possible without compromising image quality or the quantification precision of clinical MPS. METHODS The imaging data of patients with normal myocardial perfusion and 30 patients with mid-sized to large perfusion defects who had undergone stress (99m)Tc-tetrofosmin MPS were postprocessed. Low-dose (361 ± 60 MBq) and high-dose (725 ± 142 MBq) (99m)Tc-tetrofosmin scans were included, with 6-min and 4-min scanning times, respectively. List-mode SPECT data were reconstructed with CT-based attenuation correction and with full as well as 50% and 75% reductions in acquisition time to simulate the corresponding relative dose reductions. The reconstructed SPECT images were analyzed to calculate global MPS defect size and regional defect size for 3 coronary artery territories-left anterior descending, left circumflex, and right-as well as left ventricular (LV) volume and ejection fraction. RESULTS For patients with normal MPS results, there were no differences in defect size, LV volume, or ejection fraction, regardless of whether 50% or 75% reduction was used. For patients with abnormal MPS results, at a 50% reduction there was a significant difference in global defect size but not in regional defect size in the left anterior descending, left circumflex, and right coronary artery territories, whereas at a 75% reduction the difference was statistically significant in all territories, including the difference in global defect size. Nonetheless, differences in the defect size were minimal. The LV end-diastolic and end-systolic volumes and LV ejection fraction were not significantly different, regardless of whether 50% or 75% dose reduction was used. CONCLUSION Ultra-low-dose (<190 MBq) MPS even with short imaging times (<6 min) is feasible using a hybrid CZT SPECT/CT camera without compromising image quality or significantly altering quantification of myocardial perfusion or LV function. We demonstrated that an additional 50% reduction in the current low-dose recommendations from the American Society of Nuclear Cardiology guidelines for (99m)Tc-labeled MPS is highly feasible while retaining short imaging protocols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms

Objective(s): A novel IQ-SPECTTM method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECTTM (IQ-mode),conventional (180° apart: C-mode) and L-mode (90° apart: L-mode) systems. We assessed spatial resolution, image reproducibility and quantifiability using various physical phantoms. Materials and Me...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 6  شماره 

صفحات  -

تاریخ انتشار 2016