Measuring surface potential components necessary for transmembrane current computation using microfabricated arrays.
نویسندگان
چکیده
This study was designed to test the feasibility of using microfabricated electrodes to record surface potentials with sufficiently fine spatial resolution to measure the potential gradients necessary for improved computation of transmembrane current density. To assess that feasibility, we recorded unipolar electrograms from perfused rabbit right ventricular free wall epicardium (n = 6) using electrode arrays that included 25-microm sensors fabricated onto a flexible substrate with 75-microm interelectrode spacing. Electrode spacing was therefore on the size scale of an individual myocyte. Signal conditioning adjacent to the sensors to control lead noise was achieved by routing traces from the electrodes to the back side of the substrate where buffer amplifiers were located. For comparison, recordings were also made using arrays built from chloridized silver wire electrodes of either 50-microm (fine wire) or 250-microm (coarse wire) diameters. Electrode separations were necessarily wider than with microfabricated arrays. Comparable signal-to-noise ratios (SNRs) of 21.2 +/- 2.2, 32.5 +/- 4.1, and 22.9 +/- 0.7 for electrograms recorded using microfabricated sensors (n = 78), fine wires (n = 78), and coarse wires (n = 78), respectively, were found. High SNRs were maintained in bipolar electrograms assembled using spatial combinations of the unipolar electrograms necessary for the potential gradient measurements and in second-difference electrograms assembled using spatial combinations of the bipolar electrograms necessary for surface Laplacian (SL) measurements. Simulations incorporating a bidomain representation of tissue structure and a two-dimensional network of guinea pig myocytes prescribed following the Luo and Rudy dynamic membrane equations were completed using 12.5-microm spatial resolution to assess contributions of electrode spacing to the potential gradient and SL measurements. In those simulations, increases in electrode separation from 12.5 to 75.0, 237.5, and 875.0 microm, which were separations comparable to the finest available with our microfabricated, fine wire, and coarse wire arrays, led to 10%, 42%, and 81% reductions in maximum potential gradients and 33%, 76%, and 96% reductions in peak-to-peak SLs. Maintenance of comparable SNRs for source electrograms was therefore important because microfabrication provides a highly attractive methods to achieve spatial resolutions necessary for improved computation of transmembrane current density.
منابع مشابه
Analytical Modeling of Magnetic Field Distribution in Inner Rotor Brushless Magnet Segmented Surface Inset Permanent Magnet Machines
Brushless permanent magnet surface inset machines are interested in industrial applications due to their high efficiency and power density. Magnet segmentation is a common technique in order to mitigate cogging torque and electromagnetic torque components in these machines. An accurate computation of magnetic vector potential is necessary in order to compute cogging torque, electromagnetic torq...
متن کاملDetermination of heterogeneous electron transfer rate constants at microfabricated iridium electrodes
There has been an increasing use of both solid metal and microfabricated iridium electrodes as substrates for various types of electroanalysis. However, investigations to determine heterogeneous electron transfer rate constants on iridium, especially at an electron beam evaporated or dc magnetron sputtered surface, have not previously been performed. This paper compares the results of these mic...
متن کاملFabrication and operation of a two-dimensional ion-trap lattice on a high-voltage microchip.
Microfabricated ion traps are a major advancement towards scalable quantum computing with trapped ions. The development of more versatile ion-trap designs, in which tailored arrays of ions are positioned in two dimensions above a microfabricated surface, will lead to applications in fields as varied as quantum simulation, metrology and atom-ion interactions. Current surface ion traps often have...
متن کاملA solution method for the determination of cardiac potential distributions with an alternating current source.
A recently presented solution method for the bidomain model (Johnston et al. 2006), which involves the application of direct current for studying electrical potential in a slab of cardiac tissue, is extended here to allow the use of an applied alternating current. The advantage of using AC current, in a four-electrode method for determining cardiac conductivities, is that instead of using 'clos...
متن کاملDesign of Nondestructive System for Hardness of Carbonitrided Steel Parts Using Eddy Current Testing Method: Case study on the Tappet Parts
In this paper, a non-destructive eddy current test system was designed to evaluate the surface hardness of the carbonitrided steel parts. For this purpose, various samples of the tappet were used after the surface hardening and grinding operations as control samples and, if necessary, were subjected to destructive and non-destructive tests. Microstructural studies were performed with a microsco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 289 6 شماره
صفحات -
تاریخ انتشار 2005