SSFP and GRE phase contrast imaging using a three-echo readout.

نویسندگان

  • Jon-Fredrik Nielsen
  • Krishna S Nayak
چکیده

A technique for rapid in-plane phase-contrast imaging with high signal-to-noise ratio (SNR) is described. Velocity-encoding is achieved by oscillating the readout gradient, such that each 2DFT phase-encode is acquired three times following a single RF slice-selective excitation. Three images are reconstructed, from which both flow velocity and local resonance offset are calculated. This technique is compatible with both gradient-recalled echo (GRE) and balanced steady-state free precession (SSFP) imaging using a single steady-state. The proposed technique enables 1D velocity mapping with 40% higher temporal resolution and 80% higher SNR, compared to conventional PC-MRI using bipolar velocity-encoding gradient pulses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel method of increasing the contrast to noise ratio of phase images using balanced SSFP

Introduction Balanced SSFP (bSSFP) has particular advantages over GRE [1, 2]. However, with few exceptions [2, 3], most of the bSSFP studies have utilized only the image magnitude and ignored the image phase. Recently at high field (≥ 7 Tesla), contrast based on resonance frequency shifts (or phase in gradient-echo MRI) has allowed improved visualization of fine-scale structures in brain [4]. T...

متن کامل

Liver lesion conspicuity during real-time MR-guided radiofrequency applicator placement using spoiled gradient echo and balanced steady-state free precession imaging.

PURPOSE To retrospectively evaluate the conspicuity of liver lesions in a fluoroscopic spoiled gradient echo (GRE) and a balanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) sequence. MATERIALS AND METHODS In all, 103 patients with hepatocellular carcinomas (HCC) (41) or liver metastases (67) were treated using MR-guided radiofrequency ablation in a wide-bore 1.5 T sc...

متن کامل

Free-breathing myocardial T1 mapping using magnetization-prepared slice interleaved spoiled gradient echo imaging

Background Quantitative myocardial T1 mapping and extracellular volume fraction (ECV) show promise for non-invasive assessment of cardiomyopathies. Most available T1 mapping sequences use a single slice breath-hold acquisition with balanced steady state free precession (b-SSFP) readout [1]. However, b-SSFP readout is sensitive to B0 field inhomogeneity and is potentially T2 dependent [1]. In th...

متن کامل

Myocardial first pass perfusion: steady-state free precession versus spoiled gradient echo and segmented echo planar imaging.

The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast-to-noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison ...

متن کامل

Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.

A simple phase error correction technique used for field map estimation with a generally available dual-echo gradient-echo (GRE) sequence is presented. Magnetic field inhomogeneity maps estimated using two separate GRE volume acquisitions at different echo times are prone to dynamic motion errors between acquisitions. By using the dual-echo sequence, the data are collected during two back-to-ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 58 6  شماره 

صفحات  -

تاریخ انتشار 2007