Statistical aspects of the normal visual field in short-wavelength automated perimetry.

نویسندگان

  • J M Wild
  • R P Cubbidge
  • I E Pacey
  • R Robinson
چکیده

PURPOSE To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS The sample comprised 51 normal subjects, stratified for age by decade (mean age, 55.5 years; range, 24-83 years) and experienced in white-on-white (W-W) perimetry and SWAP. One randomly assigned eye of each subject was examined on three occasions with Program 30-2 of the 640 Humphrey Field Analyzer using the Full Threshold and FASTPAC strategies for SWAP and W-W perimetries. Ocular media absorption (OMA) was assessed by the difference in scotopic sensitivity to stimuli of 410 and 560 nm. RESULTS The group mean examination time (P < 0.001) was greater for SWAP than for W-W perimetry for both the Full Threshold (15.0% longer) and FASTPAC strategies (16.8% longer). The gradient of the age-decline in Mean Sensitivity for SWAP was approximately 25% less steep when corrected for OMA than when uncorrected. The interindividual normal variability, expressed as the coefficient of variation, for SWAP without correction for OMA was 2.7 times greater (range 2.0-3.9), and with correction 1.9 times greater (range 1.4-2.9), than that for W-W perimetry. CONCLUSIONS The increased interindividual normal variability of SWAP, exacerbated by the lack of correction for OMA, currently limits the utility of SWAP in that the reduction in sensitivity required to indicate abnormality was proportionately greater than for W-W perimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Topography of the frequency doubling perimetry visual field compared with that of short wavelength and achromatic automated perimetry visual fields.

BACKGROUND Traquair described the topography of visual field sensitivity as a "hill" or "island" of vision. Achromatic automated perimetry (AAP) demonstrates this shape of the visual field in photopic conditions. Techniques claimed to target the magnocellular pathway (frequency doubling perimetry, FDP) and those using a stimulus targeting the koniocellular pathway (short wavelength (or blue on ...

متن کامل

Detection of early visual field loss in glaucoma using frequency-doubling perimetry and short-wavelength automated perimetry.

OBJECTIVE To investigate whether frequency-doubling perimetry (FDP) predicts future visual field loss with achromatic automated perimetry (AAP), just as it may be predicted with short-wavelength automated perimetry (SWAP). METHODS We recruited 62 patients selectively from an urban glaucoma practice. At the commencement of the study, each patient had ocular hypertension with normal visual fiel...

متن کامل

Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

PURPOSE To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. MET...

متن کامل

The statistical interpretation of blue-on-yellow visual field loss.

PURPOSE To evaluate short-wavelength-sensitive perimetry in the detection of glaucomatous field loss. METHODS The sample consisted of 27 normal subjects, 24 patients with primary open angle glaucoma (POAG), and 27 patients with ocular hypertension (OHT). Blue-on-yellow (B-Y) and standard (W-W) perimetry was undertaken with a modified Humphrey Field Analyzer 640 on one eye of each subject and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 1998