Application and automation of flow injection analysis (FIA) using fast responding enzyme glass electrodes to detect penicillin in fermentation broth and urea in human serum

نویسندگان

  • Helmut Meier
  • François Lantreibecq
  • Canh Tran-Minh
چکیده

An enzyme immobilization technique has been developed to determine the concentration of biological compounds. This technique has been applied to penicillinase and urease, which are crosslinked as very fine films directly onto the sensitive ends of pH glass electrodes, thereby dispensing with the need of an on-line enzyme reactor. The biosensor is incorporated in an FIA system within a magnetically stirred detection cell. Penicillin-V in fermentation broth and urea in human serum samples were detected and the results were compared with HPLC and spectrophotometric methods. On-line measurement is achieved through the automation of this FIA system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric bioanalytical flow-injection system for control of hemodialysis treatment.

A spectrophotometric flow-injection analysis (FIA) system for monitoring clinical hemodialysis is demonstrated. The role of a dialysate urea detector incorporated in this bioanalytical system is played by an optical flow-through biosensor based on Prussian Blue film with chemically linked urease forming a monomolecular layer of the enzyme. This pH-enzyme optode-FIA system is useful for the sele...

متن کامل

Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of ...

متن کامل

Flow Injection System with Potentiometric Detection for the Determination of Urea Content in Milks

Two variant manifolds of a flow injection analysis (FIA) system are described for the determination of urea content in milks. This determination consists of the enzymatic reaction of urea with urease in which ammonium ion is formed. Ammonium is converted to ammonia by adding a NaOH solution and then led to a gas diffusion unit in which it diffuses to an acceptor channel (Tris/HCl, pH 7.5). Here...

متن کامل

The Application of Membrane Distillation for Broth Separation in Membrane Bioreactors

The possibility of applying membrane distillation to support the fermentation process was investigated. The capillary polypropylene membranes were assembled in the membrane modules. The studies were carried out using the standard solutions containing the compounds frequently occurring in the broths such as ethanol, citric, acetic and lactic acids, glycerol and 1,3-propanediol. The performance o...

متن کامل

The role of flow injection analysis within the framework of an automated laboratory

Flow Injection Analysis (FIA) was invented at roughly the same time by two quite dissimilar research groups [1,2]. FIA was patented by both groups in 1974; a year also marked by the publication of the first book on automatic chemical analysis [3]. This book was a major undertaking for its authors and it is hoped that it has added to the knowledge of those analysts attempting to automate their w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Automatic Chemistry

دوره 14  شماره 

صفحات  -

تاریخ انتشار 1992