Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis

نویسندگان

  • Caroline Dahlqvist
  • Sebahat Ocak
  • Maximilien Gourdin
  • Anne Sophie Dincq
  • Laurie Putz
  • Jean-Paul d'Odémont
چکیده

Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Covered metallic stent for ischemic hilar biliary stricture.

Compared with surgery, endoscopic treatment is safe and highly effective for a postoperative hilar benign bile duct stricture (BDS). However, the long-term outcome of conventional placement of a single biliary stent for hilar benign BDS is generally poor. Although the placement of multiple biliary stents is preferred, multiple stenting in a BDS is difficult. Alternatively, single or multiple st...

متن کامل

Hole-making technique for the treatment for acute pancreatitis due to placement of a fully covered duodenal metallic stent.

Duodenal stent placement has been developed as an alternative to surgical gastrojejunostomy [1]. Compared with uncovered metallic stents, duodenal fully covered metallic stents offer advantages, such as the prevention of tumor ingrowth, and thus lower occlusion rates [2]. However, duodenal fully covered metallic stents also have several disadvantages, such as stent migration [3]. Acute pancreat...

متن کامل

Pericarditis: a rare complication of fully covered self-expandable metallic stent in postoperative benign anastomotic stricture.

Benign esophageal strictures are traditionally treated by endoscopic dilation with bougies or balloons [1,2]. Fully covered, self-expandable, metallic stents (SEMS) have been used in the treatment of benign esophageal disease, with the benefits of removability and low incidence of tissue hyperplasia [3]. However, significant complications, such as stent migration, recurrent stricture, or erosio...

متن کامل

Fully covered self-expandable metal stent in tracheobronchial disorders: clinical experience.

BACKGROUND The third-generation fully covered self-expandable metallic stent (SEMS) has been developed to solve the problems of difficult removal and in-stent granuloma formation related to the uncovered or partially covered type. There are few written reports about the performance of this type of stents with early encouraging results. OBJECTIVES To report and analyse our experience with the ...

متن کامل

Initial experience in the Czech Republic

Use of stents for treatment of benign stenoses of the gastrointestinal tract is associated with several problems and drawbacks. Uncovered metallic stents induce early mucosal hyperplastic reaction (with overand/or ingrowth); covered metallic and plastic stents are associated with a higher risk of migration and lower flexibility and shorter/lower radial force. Re ports on their use provide contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016