CPOL: Complex phase order likelihood as a similarity measure for MR-CT registration

نویسندگان

  • Alexander Wong
  • David A. Clausi
  • Paul W. Fieguth
چکیده

A novel similarity measure for registering magnetic resonance (MR) and computed tomography (CT) images has been designed and built. MR-CT registration methods often rely on the statistical intensity relationship between the images. The proposed similarity measure instead depends on the statistical relationship between the complex phase order between the images. By utilizing the complex phase order likelihood (CPOL) as a similarity measure, structural relationships instead of intensity relationships are explicitly used. This approach can be advantageous for MR-CT registration, where the intensities of the CT imagery have highly complex and nonlinear relationships with the intensities of corresponding MR imagery but simpler linear structural relationships. This new similarity measure has been tested on real MR-CT 3D volumes and has been evaluated based on fiducial registration error to determine alignment accuracy. Quantitative results show that CPOL is capable of achieving comparable alignment accuracy when compared to normalized mutual information, while being more robust to imaging artifacts such as noise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps

Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...

متن کامل

Learning the Similarity Measure for Multi-Modal 3D Image Registration

Multi-modal image registration is a challenging problem in medical imaging. The goal is to align anatomically identical structures, however, their appearance in images acquired with different imaging devices, such as for example CT or MR, may be very different. Registration algorithms generally try to deform one image, the floating image, such that it matches with a second, the reference image,...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information

Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical image analysis

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2010