Impact of Environmental Factors on Legionella Populations in Drinking Water

نویسندگان

  • David Otto Schwake
  • Absar Alum
  • Morteza Abbaszadegan
  • Mark W. LeChevallier
چکیده

To examine the impact of environmental factors on Legionella in drinking water distribution systems, the growth and survival of Legionella under various conditions was studied. When incubated in tap water at 4 °C, 25 °C, and 32 °C, L. pneumophila survival trends varied amongst the temperatures, with the stable populations maintained for months at 25 °C and 32 °C demonstrating that survival is possible at these temperatures for extended periods in oligotrophic conditions. After inoculating coupons of PVC, copper, brass, and cast iron, L. pneumophila colonized biofilms formed on each within days to a similar extent, with the exception of cast iron, which contained 1-log less Legionella after 90 days. L. pneumophila spiked in a model drinking water distribution system colonized the system within days. Chlorination of the system had a greater effect on biofilm-associated Legionella concentrations, with populations returning to pre-chlorination levels within six weeks. Biofilms sampled from drinking water meters collected from two areas within central Arizona were analyzed via PCR for the presence of Legionella. Occurrence in only one area indicates that environmental differences in water distribution systems may have an impact on the survival of Legionella. These results document the impact of different environmental conditions on the survival of Legionella in water.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevention of hospital-acquired legionellosis.

PURPOSE OF REVIEW The incidence of hospital-acquired legionellosis appears to be increasing. Presence of Legionella in the hospital drinking water is the only risk factor known with certainty to be predictive of risk for contracting Legionnaires' disease. RECENT FINDINGS Given the high frequency of infection by nonpneumophila and nonserogroup 1 species, both Legionella respiratory culture on ...

متن کامل

Influence of temperature, chlorine residual and heavy metals on the presence of Legionella pneumophila in hot water distribution systems.

The microbiological colonisation of buildings and man-made structures often occurs on the walls of plumbing systems; therefore, monitoring of opportunistic pathogens such as Legionella pneumophila (L. pneumophila), both in water distribution mains and in consumers' plumbing systems, is an important issue according to the international and national guidelines that regulate the quality of drinkin...

متن کامل

Isolation of Legionella species from drinking water.

Three different species of Legionella were recovered from samples of water taken from chlorinated public water supplies where no coliform bacteria were simultaneously detected. Five of 856 samples yielded Legionella isolates. Three isolates were identified as Legionella pneumophila serogroup 1, the fourth was identified as Legionella dumoffii, and the fifth was identified as Legionella jordanis...

متن کامل

Evaluation of drinking water quality indices (case study: Bushehr province, Iran)

Background: Internal corrosion and the formation of scale in water distribution pipes are the most important problems for an urban water distribution system. Physical, chemical, or biological factors can lead to these two processes. Internal corrosion and scale formation can impact health, economy, and aesthetics. This study assessed the physicochemical quality parameters and evaluated the pote...

متن کامل

Survival and multiplication of Legionella pneumophila in municipal drinking water systems.

Studies were conducted to investigate the survival and multiplication of Legionella spp. in public drinking water supplies. An attempt was made, over a period of several years, to isolate legionellae from a municipal system. Sampling sites included the river water supply, treatment plant, finished water reservoir system, mains, and distribution taps. Despite the use of several isolation techniq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015