Comparison of NucliSens and Roche Monitor assays for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma.
نویسندگان
چکیده
We compared the performance of Organon Teknika's NucliSens and Roche Diagnostic Systems' Monitor quantitative human immunodeficiency type 1 RNA assays. Both had similar linearity and sensitivity over most of the dynamic range of the assays, although the Monitor assay was superior at the low range of RNA values while the NucliSens assay was more consistent at higher RNA values. NucliSens generally showed less interassay variability.
منابع مشابه
Multicenter evaluation of methods to quantitate human immunodeficiency virus type 1 RNA in seminal plasma.
We have evaluated two commercially available kits (AMPLICOR MONITOR [Roche] and NASBA HIV-1 QT or NucliSens HIV-1 QT [Organon Teknika]) and two noncommercial methods for the accurate quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in seminal plasma. The same panels of coded specimens were tested on four separate occasions. Laboratories using the commercial assays employed silica...
متن کاملUse of active surveillance cultures in intensive care units.
3. Katsoulidou A, Petrodaskalaki M, Sypsa V, et al. Evaluation of the clinical sensitivity for the quantitation of human immunodeficiency virus type 1 RNA in plasma: comparison of the new Cobas TaqMan HIV-1 with three current HIV-RNA assays–LCx HIV RNA quantitative, Versant HIV-1 RNA 3.0 (bDNA) and Cobas Amplicor HIV-1 Monitor v1.5. J Virol Methods 2006; 131:168–74. 4. Damond F, Roquebert B, Be...
متن کاملComparison of levels of human immunodeficiency virus type 1 RNA in plasma as measured by the NucliSens nucleic acid sequence-based amplification and Quantiplex branched-DNA assays.
This study compared levels of human immunodeficiency virus type 1 RNA in plasma as measured by the Quantiplex branched-DNA and NucliSens nucleic acid sequence-based amplification assays. RNA was detectable in 118 of 184 samples (64.13%) by the Quantiplex assay and in 171 of 184 samples (92.94%) by the NucliSens assay. Regression analysis indicated that a linear relationship existed between the ...
متن کاملEvaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma
Human immunodeficiency virus type 1 (HIV-1) genetic diversity poses a challenge to reliable viral load monitoring. Discrepancies between different testing platforms have been observed, especially for non-clade-B virus. Therefore we compare, in antiretroviral therapy (ART)-naïve South African subjects predominantly infected with HIV-1 clade-C, three commercially available assays: the COBAS Ampli...
متن کاملMulticenter evaluation of the performance characteristics of the NucliSens HIV-1 QT assay used for quantitation of human immunodeficiency virus type 1 RNA.
The analytical performance of the NucliSens HIV-1 QT assay, a highly sensitive test based on nucleic acid sequence-based amplification technology, was evaluated in a multicenter trial. Assay specificity was evaluated with 502 plasma (EDTA) specimens from human immunodeficiency virus type 1 (HIV-1)-seronegative volunteer donors. No HIV-1 RNA was reported in any of the donor specimens. Analytical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 37 2 شماره
صفحات -