Comparison of two automated quantitative immunoassays for the determination of C reactive protein concentrations.

نویسندگان

  • E A Barclay
  • J E Coia
  • P C Kale
  • R G Masterton
چکیده

Two quantitative, automated methods for the determination of C reactive protein (CRP) were compared: turbidimetry (Cobas Fara II, Roche, Welwyn Garden City, UK) and fluorescence polarisation TDx, Abbott, Wokingham, UK). One hundred and twenty routine serum samples submitted for measurement of CRP were tested using both procedures. The results were compared using regression line analysis and showed a high degree of correlation (r2 = 0.99, X coefficient = 1.01, constant = 0.11). C reactive protein can be accurately measured using the automated turbidimetric method which can be recommended as an alternative to fluorescence polarisation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two Methods: Qualitative and Quantitative Study of C - Reactive Protein

Abstract Background and Objective: C - reactive protein (CRP) is an acute phase protein produced in liver. It is less than 5 mg per deciliter in the serum and body fluids of normal individuals, but it is increased suddenly within a few hours following inflammatory reaction. In bacterial and viral infections, active rheumatic fever, acute myocardial infarction and rheumatoid arthritis are a...

متن کامل

THE EFFECT OF AN ENDURANCE SWIMMING SESSION ON CLARA CELL PROTEIN AND CRP CONCENTRATIONS IN ELITE AND RECREATIONAL ENDURANCE MALE SWIMMERS

Background & Aims: The presence of epithelial cells in the blood is a symptom of cellular damage. Clara's cell proteins are the epithelial cells of the lungs and the respiratory tract, also, the existence of cytokines such as reactive protein C is a sign of inflammation. The purpose of the present study was to investigate the effect of one session of endurance swimming activity on the serum con...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

Comparison of Homocysteine and C-reactive protein Levels Between Active and Inactive Veterans

Background: homocysteine and highly sensitive C-reactive protein (CRP) are two novel cardiovascular risk factors that induce atherosclerosis and myocardial infarction through inflammatory mechanisms. The aim of this study was to comparison of levels of these variables among athlete and nonathlete veterans. Methods: in this cross-sectional study two groups of athletes (N=8) and nonathlete (N=8) ...

متن کامل

Comparison of Serum Level and IL-18 Gene Expression and Reactive Protein in Patients with Type 2 Diabetes with Metabolic Syndrome and Healthy People

Introduction: Metabolic syndrome is a common clinical anomaly, with an increased risk of developing type 2 diabetes and cardiovascular risk factors. Increased inflammatory mediators, such as reactive protein,as well as the inflammatory cytokines can be associated with the incidence and progression of metaboli syndrome and type 2 diabetes.   Materials & Methods: This study was performed on 35 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 1994