Differential immunoadsorption coupled with rate nephelometry for estimation of DNA-binding immunoglobulins.

نویسندگان

  • V A DeBari
  • J Nicotra
  • J F Blaney
  • E F Schultz
  • M A Needle
چکیده

We describe a technique for estimating the mass of anti-DNA antibodies by immunonephelometry of serum immunoglobulins (IgG, IgA, IgM) before and after adsorption onto DNA bound to agarose-polylysine columns. Sixteen patients with systemic lupus erythematosus and 16 age- and sex-matched controls were studied. Precision was determined for high-value (in 10 patients) and low-value (in nine controls) ranges for each of the immunoglobulins. Within-run CVs ranged from 3.0% (IgG, controls) to 11.8% (IgA, patients); between-run CVs ranged from 15.5% (IgG, patients) to 25.2% (IgM, patients). We found anti-DNA antibody concentrations (mean +/- SD) in systemic lupus erythematosus of 1.981 +/- 1.015 g/L for IgG (controls: 0.243 +/- 0.231, p less than 0.001), 0.257 +/- 0.215 g/L for IgA (controls: 0.038 +/- 0.035, p less than 0.001), and 0.282 +/- 0.234 g/L for IgM (controls: 0.191 +/- 0.165, p greater than 0.05). Sensitivity and linearity are such that fivefold dilutions of patients' serum with either a buffered albumin solution or control serum yielded values close to the expected values for IgG. Similarly diluted sera gave inordinately high values in the radiometric binding assay. Neither parametric (linear regression) nor nonparametric correlation methods (Spearman's rank and Kendall's tau) show a significant correlation between patients' data obtained by the present technique and that by a radiometric binding assay (p greater than 0.05), although combined data from patients and controls demonstrate a significant nonparametric correlation (p less than 0.005 for Spearman's and p less than 0.02 for Kendall's).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

Iterative scheme to a coupled system of highly nonlinear fractional order differential equations

In this article, we investigate sufficient conditions for existence of maximal and minimal solutions to a coupled system of highly nonlinear differential equations of fractional order with mixed type boundary conditions. To achieve this goal, we apply monotone iterative technique together with the method of upper and lower solutions. Also an error estimation is given to check the accuracy of th...

متن کامل

Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radi...

متن کامل

Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.

Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA prote...

متن کامل

Cu(II) and Zn(II) complexes with unsymmetrical tetradentate Schiff base ligands: Synthesis, spectral characterization, antimicrobial assay and DNA binding property

The reaction of copper(II) chloride and zinc(II) chloride with N-(2-methylphenyl)-3-(1'-salicylaldehydene-2'-imine-ethane)-butanamide(H2L2a) or (MPSB), N-(2-methylphenyl)-3-(1'-(3'-methoxysalicylaldehydene-2'-imine-ethane)-butanamide (H2L2b) or (MPMSB) and N-(2-methylphenyl)-3-(1'-(2'-hydroxyacetylene-2'-imine-ethane)-butanamide (H2L2c) (MPHB) leads to the formation of a series of new complexes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 1984