A half-scan error reduction based algorithm for cone-beam CT
نویسندگان
چکیده
The most popular Feldkamp algorithm for cone-beam image reconstruction assumes a scanning circle, and performs well only with a small cone angle. In this report, we propose a Feldkamp-type algorithm to increase the cone angle by several folds at a radiation dose comparable to that required by the classic Feldkamp algorithm. In our scheme, two half-scans of different radii are used. Then, approximate reconstructions from two half-scans are combined to produce a superior image volume by utilizing a relationship between the half-scan reconstruction error and the scanning locus radius. The merit of this half-scan error reduction based (HERB) algorithm is demonstrated in numerical simulation with the 3D Shepp-Logan phantom.
منابع مشابه
Usability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملA Grangeat-type half-scan algorithm for cone-beam CT.
Modern CT and micro-CT scanners are rapidly moving from fan-beam toward cone-beam geometry. Half-scan CT algorithms are advantageous in terms of temporal resolution, and widely used in fan-beam and cone-beam geometry. While existing half-scan algorithms for cone-beam CT are in the Feldkamp framework, in this paper we compensate missing data explicitly in the Grangeat framework, and formulate a ...
متن کامل3D Analytic Cone-Beam Reconstruction for Multiaxial CT Acquisitions
A conventional 3rd generation Computed Tomography (CT) system with a single circular source trajectory is limited in terms of longitudinal scan coverage since extending the scan coverage beyond 40 mm results in significant cone-beam artifacts. A multiaxial CT acquisition is achieved by combining multiple sequential 3rd generation axial scans or by performing a single axial multisource CT scan w...
متن کاملFDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)
A cone beam circular half-scan scheme is becoming an attractive imaging method in cone beam CT since it improves the temporal resolution. Traditionally, the redundant data in the circular half-scan range is weighted by a central scanning plane-dependent weighting function; FDK algorithm is then applied on the weighted projection data for reconstruction. However, this scheme still suffers the at...
متن کاملHalf-scan cone-beam CT fluoroscopy with multiple x-ray sources.
To develop volumetric micro-CT fluoroscopy for small animal imaging, we have proposed a cone-beam system with multiple x-ray sources. In this paper, we extend Parker's single-source half-scan weighting scheme to the case of an odd number of x-ray sources that are equiangularly distributed, and apply it for half-scan Feldkamp-type reconstruction in this unique geometry. In the numerical simulati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004