Prototype Development of a Thermoluminescence Dosimeter Based on Monte Carlo Simulation Methods

نویسندگان

  • C. Hranitzky
  • H. Stadtmann
  • P. Kindl
چکیده

The European Directive 96/29/EURATOM and adapted national regulations on radiation protection are claiming new limits of radiation exposure and the introduction of new measuring quantities. Dosimeters for area monitoring of penetrating X-ray and gamma radiation have to measure the ICRU operational quantity ambient dose equivalent, H*(10). In this paper, the development stages of a passive H*(10) area dosimeter based on thermoluminescence detectors (TLDs) are described. The design of the dosimeter and the optimization of the combined energy and directional response are almost completely performed by MCNP Monte Carlo computer simulations. At the end of the first prototype development stage, two prototypes containing three TLD cards were manufactured according to the simulation results. The optimization method and dosemeter properties could be confirmed by the concluding verification experiment. The prototypes of the second development phase were especially optimized for measuring independent of the direction of incident photon radiation fields. Additionally, an aluminium cap was introduced for environmental protective purposes. The third-stage prototypes currently under testing were planned as the final stage of the presented dosimeter development process. Their design was optimized on meeting specific requirements of passive area monitoring devices in routine applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effects of Inhomogeneities on Dose Profiles Using Polymer Gel Dosimeter and Monte Carlo Simulation in Gamma Knife

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

متن کامل

Application of Monte Carlo Simulation in the Assessment of European Call Options

In this paper, the pricing of a European call option on the underlying asset is performed by using a Monte Carlo method, one of the powerful simulation methods, where the price development of the asset is simulated and value of the claim is computed in terms of an expected value. The proposed approach, applied in Monte Carlo simulation, is based on the Black-Scholes equation which generally def...

متن کامل

Megavoltage dose enhancement of gold nanoparticles for different geometric set-ups: Measurements and Monte Carlo simulation

Background: Gold nanoparticles (GNPs) have been shown as a good radiosensitizer. In combination with radiotherapy, several studies with orthovoltage X-rays have shown considerable dose enhancement effects. This paper reports the dose enhancement factor (DEF) due to GNPs in 18 megavoltage (MV) beams. Materials and Methods: Different geometrical 50-nm GNPs configurations at a concentrati...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Estimating Reliability in Mobile ad-hoc Networks Based on Monte Carlo Simulation (TECHNICAL NOTE)

Each system has its own definition of reliability. Reliability in mobile ad-hoc networks (MANET) could be interpreted as, the probability of reaching a message from a source node to destination, successfully. The variability and volatility of the MANET configuration makes typical reliability methods (e.g. reliability block diagram) inappropriate. It is because, no single structure or configurat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004