UPS Parallel Balanced Operation Without Explicit Estimation of Reactive Power - A Simpler Scheme

نویسندگان

  • Edgar Campos Furtado
  • Luis Antonio Aguirre
  • Leonardo A. B. Tôrres
چکیده

A novel scheme of the well-known technique for parallel operation of uninterruptible power supply systems, namely frequency and voltage droop control method, is presented. The innovation relies on active power estimation, together with the use of a piecewise-continuous nonlinear function, in order to eliminate the need for costly cascaded low-pass filters usually employed to estimate the reactive power. Moreover, the whole scheme is derived in the time domain on a state-space approach. As a consequence, models that are lower order and more amenable to nonlinear analysis are obtained. Simulated results for two UPS parallel operation connected to a resistive load are presented. The results indicate that the novel technique leads to a proper load sharing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Model Predictive Control of Distributed Energy Resources with Predictive Set-Points for Grid-Connected Operation

This paper proposes an MPC - based (model predictive control) scheme to control active and reactive powers of DERs (distributed energy resources) in a grid - connected mode (either through a bus with its associated loads as a PCC (point of common coupling) or an MG (micro - grid)). DER may be a DG (distributed generation) or an ESS (energy storage system). In the proposed scheme, the set - poin...

متن کامل

Reactive and Active Power Control of Grid WECS Based on DFIG and Energy Storage System under both Balanced and Unbalanced Grid Conditions

This paper focuses on improving the active and reactive power control of Wind Energy Conversion System (WECS) by employing the Battery Energy Storage System (BESS) and controlling the frequency and voltage regulation instantaneously. The proposed power control scheme is composed of two control loops so that they are implemented and designed for active power control and controlling the reactive ...

متن کامل

Comparison of MRAS Based Rotor Resistance Estimator Using Reactive Power and Flux Based Techniques for Space Vector PWM Inverter Fed Induction Motor Drives

The performance of Vector Controlled Induction Motor drive depends on the accuracy of rotor resistance which will vary with temperature and frequency. The MRAS approach using reactive power and flux as a state variable for rotor resistance estimation makes MRAS computationally simpler and easy to design. In this paper, Rotor Flux based MRAS (RF-MRAS) and Reactive Power based MRAS (RP-MRAS) for ...

متن کامل

A Simplified Droop Method Implementation in Parallel Ups Inverters with Proportional-resonant Controller

In this paper, a simpler implementation of the well-known droop method for the control of parallel Uninterruptible Power Supply (UPS) systems is presented. In this method, in the power-sharing control scheme, the output current is calculated by software without the need for a current sensor, resulting in a simpler and cheaper structure. By doing so, the number of feedback sensors is reduced fro...

متن کامل

A Local Power Control Scheme for Electronically Interfaced Distributed Generators in Islanded Microgrids

The conventional real power-frequency and reactive power-voltage droop characteristics are commonly employed to share the electric power among parallel distributed generation (DG) units. Despite some advantages such as easy implementation and no need for communication infrastructure, inaccurate reactive power sharing is one of the main disadvantages of conventional droop control. This paper pre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE Trans. on Circuits and Systems

دوره 55-II  شماره 

صفحات  -

تاریخ انتشار 2008