Balloon dilatation of congenital aortic valve stenosis in infants and children: short term and intermediate results.
نویسندگان
چکیده
Percutaneous balloon dilatation of the aortic valve was attempted in 25 consecutive patients with stenosis. The aortic valve diameters were normal for age. The balloon catheters were placed retrogradely, and their diameters were within 1-2 mm of the valve diameter and 3 (13 patients) or 6 cm (recent 12 patients) long. After dilatation the pressure gradients across the aortic valve were reduced significantly and the valve areas, measured in 10 patients, increased. Aortic regurgitation was detected in six patients before (grade I) the procedure and in 15 patients (6 grade I, 6 grade II, 3 grade III) after the procedure. In one patient the aortic valve could not be crossed and in three there was no reduction in the pressure drop. Nine patients have a sustained reduction in Doppler assessed gradients. There were vascular complications in 12 and these required surgical intervention in three patients. Balloon dilatation seems to be an effective short term palliative procedure in patients with congenital stenosis of the aortic valve.
منابع مشابه
Immediate and Short-term Follow-Up of Aortic Coarctation Balloon Angioplasty and Stenting
Background Aortic Coarcatation (CoA) is one of the congenital heart diseases with the rate of 5-8% of Coronary heart diseases(CHDs). Balloon angioplasty is now one of the effective way of treatment for CoA, native or Re-coarctation (Re-CoA). We aimed to assess the immediate, and short term response to angioplasty and stenting, and also complications. Materials and Methods Balloon angioplasty wi...
متن کاملمقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران
Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...
متن کاملBalloon Aortic Valvuloplasty
Following the description by Lababidi in 1983 of balloon aortic valvuloplasty, it has been adopted by several groups of workers for relief of aortic valve stenosis. The indications for the procedure are peak-to-peak systolic pressure gradients in excess of 50 mmHg with symptoms or ECG changes or a gradient greater than 70 mmHg irrespective of the symptoms or ECG changes. One or more balloon dil...
متن کاملAortic balloon dilatation for congenital aortic stenosis: report of 90 cases (1986-98).
OBJECTIVE To review 12 years of experience of balloon aortic valvoplasty in childhood. DESIGN Early and mid-term clinical and instrumental evaluation of 104 consecutive balloon aortic valvoplasties performed from 1986 to 1998. SETTING A tertiary referral centre for congenital heart disease. PATIENTS 90 patients with congenital aortic stenosis: 20 neonates (group 1), 16 infants (group 2), ...
متن کاملBalloon dilatation of the aortic valve for congenital aortic stenosis in childhood.
Balloon dilatation of the aortic valve was attempted in 34 consecutive children aged 16 months to 17 years (median 7 years), weight range 9-60 (median 22) kg. Previous surgical valvotomy had been performed in two patients (twice in one of them). The valve was not crossed in one patient. In the remaining 33 patients the pressure difference between the left ventricle and the ascending aorta durin...