TMSEEG: A MATLAB-Based Graphical User Interface for Processing Electrophysiological Signals during Transcranial Magnetic Stimulation

نویسندگان

  • Sravya Atluri
  • Matthew Frehlich
  • Ye Mei
  • Luis Garcia Dominguez
  • Nigel C. Rogasch
  • Willy Wong
  • Zafiris J. Daskalakis
  • Faranak Farzan
چکیده

Concurrent recording of electroencephalography (EEG) during transcranial magnetic stimulation (TMS) is an emerging and powerful tool for studying brain health and function. Despite a growing interest in adaptation of TMS-EEG across neuroscience disciplines, its widespread utility is limited by signal processing challenges. These challenges arise due to the nature of TMS and the sensitivity of EEG to artifacts that often mask TMS-evoked potentials (TEP)s. With an increase in the complexity of data processing methods and a growing interest in multi-site data integration, analysis of TMS-EEG data requires the development of a standardized method to recover TEPs from various sources of artifacts. This article introduces TMSEEG, an open-source MATLAB application comprised of multiple algorithms organized to facilitate a step-by-step procedure for TMS-EEG signal processing. Using a modular design and interactive graphical user interface (GUI), this toolbox aims to streamline TMS-EEG signal processing for both novice and experienced users. Specifically, TMSEEG provides: (i) targeted removal of TMS-induced and general EEG artifacts; (ii) a step-by-step modular workflow with flexibility to modify existing algorithms and add customized algorithms; (iii) a comprehensive display and quantification of artifacts; (iv) quality control check points with visual feedback of TEPs throughout the data processing workflow; and (v) capability to label and store a database of artifacts. In addition to these features, the software architecture of TMSEEG ensures minimal user effort in initial setup and configuration of parameters for each processing step. This is partly accomplished through a close integration with EEGLAB, a widely used open-source toolbox for EEG signal processing. In this article, we introduce TMSEEG, validate its features and demonstrate its application in extracting TEPs across several single- and multi-pulse TMS protocols. As the first open-source GUI-based pipeline for TMS-EEG signal processing, this toolbox intends to promote the widespread utility and standardization of an emerging technology in brain research.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate and Rapid Estimation of Phosphene Thresholds (REPT)

To calibrate the intensity of transcranial magnetic stimulation (TMS) at the occipital pole, the phosphene threshold is used as a measure of cortical excitability. The phosphene threshold (PT) refers to the intensity of magnetic stimulation that induces illusory flashes of light (phosphenes) on a proportion of trials. The existing PT estimation procedures lack the accuracy and mathematical rigo...

متن کامل

Safety and Therapeutic Effects of Repetitive Transcranial Magnetic Stimulation and Behavior Therapy in a Pregnant Woman: Case Report

In this study, the authors reported a case of woman with severe compulsion who became pregnant during the Repetitive transcranial magnetic stimulation. We carried out Repetitive transcranial magnetic stimulation and behavior therapy simultaneously after repeated medications' refraction. The patient received 20 sessions 1 Hz Repetitive transcranial magnetic stimulation in right dorsolateral pref...

متن کامل

Potensoft: MATLAB-based software for potential field data processing, modeling and mapping

An open-source software including an easy-to-use graphical user interface (GUI) has been developed for processing, modeling and mapping of gravity and magnetic data. The program, called Potensoft, is a set of functions written in MATLAB. The most common application of Potensoft is spatial and frequency domain filtering of gravity and magnetic data. The GUI helps the user easily change all the r...

متن کامل

Digital Signal Processing System of Ultrasonic Signals

In general the ultrasonic testing is used for flaw detection and localization in tested materials. Flaws in materials are commonly characterized in measured ultrasonic signals by faults echoes. Ultrasonic signals measured on materials with coarse grained structure contain relative high level of noise. This undesirable part of ultrasonic signal should be reduced to make the fault echo detection ...

متن کامل

Clinician accessible tools for GUI computational models of transcranial electrical stimulation: BONSAI and SPHERES.

Computational models of brain current flow during transcranial electrical stimulation (tES), including transcranial direct current stimulation (tDCS) and transcranial alternating current stimulation (tACS), are increasingly used to understand and optimize clinical trials. We propose that broad dissemination requires a simple graphical user interface (GUI) software that allows users to explore a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016