Task-Based Design of Fluence Field Modulation in CT for Model-Based Iterative Reconstruction.

نویسندگان

  • Grace J Gang
  • Jeffrey H Siewerdsen
  • J Webster Stayman
چکیده

A task-driven imaging framework for prospective fluence field modulation (FFM) is developed in this paper. The design approach uses a system model that includes a parameterized FFM acquisition and model-based iterative reconstruction (MBIR) for image formation. Using prior anatomical knowledge (e.g. from a low-dose 3D scout image), accurate predictions of spatial resolution and noise as a function of FFM are integrated into a task-based objective function. Specifically, detectability index (d'), a common metric for task-based image quality assessment, is computed for a specific formulation of the imaging task. To optimize imaging performance in across an image volume, a maximin objective function was adopted to maximize the minimum detectability index for many locations sampled throughout the volume. To reduce the dimensionality, FFM patterns were represented using wavelet bases, the coefficients of which were optimized using the covariance matrix adaptation evolutionary strategy (CMA-ES) algorithm. The optimization was performed for a mid-frequency discrimination task involving a cluster of micro-calcifications in an abdomen phantom. The task-driven design yielded FFM patterns that were significantly different from traditional strategies proposed for FBP reconstruction. In addition to a higher minimum d' consistent with the objective function, the task-driven approach also improved d' to a greater extent over a larger area of the phantom. Results from this work suggests that FFM strategies suitable for FBP reconstruction need to be reevaluated in the context of MBIR and that a task-driven imaging framework provides a promising approach for such optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Performance comparison of four commercial GE discovery PET/CT scanners: A monte carlo study using GATE

  Combined PET/CT scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. As the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner ...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016