Does spontaneous respiration alter pulmonary artery input impedance?

نویسندگان

  • P Castiglioni
  • M Di Rienzo
  • M Grossoni
  • R Tommasini
  • M Morpurgo
چکیده

The aim of this study was to determine whether spontaneous respiration influences pulmonary artery input impedance, a question that has received little attention in the literature. Impedance values were assessed during three different phases of the respiratory cycle, namely inspiration, expiration and postexpiration (i.e. the null respiratory flow period between expiration and the next inspiration) in five anaesthetized spontaneously breathing dogs. Firstly, impedance values during postexpiration were taken as the reference baseline, and compared with values obtained during inspiration and expiration. Then, differences between values in inspiration and in expiration were tested, taking impedance during inspiration as the baseline. Differences with respect to postexpiration were found for three parameters of input impedance: input resistance, characteristic impedance, and the frequency at the first zero-crossing of the impedance phase from negative to positive values (f(cross)). Input resistance was significantly lower in inspiration (85% of the baseline), characteristic impedance was significantly greater in inspiration and in expiration (112 and 119% respectively), and f(cross) was significantly lower in expiration (89%). By contrast, only input resistance differed significantly when inspiration was compared to expiration. Therefore, spontaneous respiration was shown to influence input impedance significantly. The observed changes in characteristic impedance and f(cross) might be explained by a stiffening of the pulmonary artery wall, due to neural and/or mechanical factors, during inspiration and expiration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary artery constriction produces a greater right ventricular dynamic afterload than lung microvascular injury in the open chest dog.

Investigators model noncardiogenic pulmonary hypertension by constricting the pulmonary artery to increase right ventricular afterload. To investigate this model's validity, we compared the right ventricular afterload, quantified as pulmonary input impedance, created by constricting the pulmonary artery and by inducing a pulmonary microvascular injury (with glass beads infused into the pulmonar...

متن کامل

Input impedance of the pulmonary arterial system in normal man. Effects of respiration and comparison to systemic impedance.

Input impedance of the pulmonary arterial system was determined in 10 subjects undergoing elective cardiac catheterization. No cardiovascular or pulmonary disease was found in these patients. In five of the subjects, systemic arterial impedance was also obtained, so that both systems could be compared. Pulmonary and systemic peripheral resistances were 79 +/- 9 dynes sec/cm5 (mean +/- SEM) and ...

متن کامل

Clinical significance of pulmonary arterial input impedance.

C Cl li in ni ic ca al l s si ig gn ni if fi ic ca an nc ce e o of f p pu ul lm mo on na ar ry y a ar rt te er ri ia al l i in np pu ut t i im mp pe ed da an nc ce e Pulmonary arterial input impedance excites the attention of few clinicians, but there are compelling reasons why they should be more interested in this subject. Physicians are well-versed in the intricacies of pulmonary vascular re...

متن کامل

Patchy deletion of Bmpr1a potentiates proximal pulmonary artery remodeling in mice exposed to chronic hypoxia.

Reduced vascular expression of bone morphogenetic protein type IA receptor (Bmpr1a) has been found in patients with pulmonary arterial hypertension. Our previous studies in mice with patchy deletion of Bmpr1a in vascular smooth muscle cells and cardiac myocytes showed decreased distal vascular remodeling despite a similar severity of hypoxic pulmonary hypertension (HPH). We speculate increased ...

متن کامل

Evaluation of Pediatric Pulmonary Artery Input Impedance Using Windkessel Models and Doppler Ultrasound: in Vitro and Clinical Studies

The m pulmonary h cardiologists of chronic th facilitated th therapeutic reactivity. H vascular rea relying on qu defined as th to mean pul hemodynami compliance estimates of compliance i In cont generated tho ratio of tim represented resistance an from the im model that e case. Signifi that depict t system using models. By e prove useful dynamics an This in models to parameters o using a mock ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 9 11  شماره 

صفحات  -

تاریخ انتشار 1996