Combining tissue-phantom ratios to provide a beam-quality specifier for flattening filter free photon beams.

نویسندگان

  • Mårten Dalaryd
  • Tommy Knöös
  • Crister Ceberg
چکیده

PURPOSE There are currently several commercially available radiotherapy treatment units without a flattening filter in the beam line. Unflattened photon beams have an energy and lateral fluence distribution that is different from conventional beams and, thus, their attenuation properties differ. As a consequence, for flattening filter free (FFF) beams, the relationship between the beam-quality specifier TPR20,10 and the Spencer-Attix restricted water-to-air mass collision stopping-power ratios, L̄/ρair (water), may have to be refined in order to be used with equivalent accuracy as for beams with a flattening filter. The purpose of this work was twofold. First, to study the relationship between TPR20,10 and L̄/ρair (water) for FFF beams, where the flattening filter has been replaced by a metal plate as in most clinical FFF beams. Second, to investigate the potential of increasing the accuracy in determining L̄/ρair (water) by adding another beam-quality metric, TPR10,5. The relationship between L̄/ρair (water) and %dd(10)x for beams with and without a flattening filter was also included in this study. METHODS A total of 24 realistic photon beams (10 with and 14 without a flattening filter) from three different treatment units have been used to calculate L̄/ρair (water), TPR20,10, and TPR10,5 using the EGSnrc Monte Carlo package. The relationship between L̄/ρair (water) and the dual beam-quality specifier TPR20,10 and TPR10,5 was described by a simple bilinear equation. The relationship between the photon beam-quality specifier %dd(10)x used in the AAPM's TG-51 dosimetry protocol and L̄/ρair (water) was also investigated for the beams used in this study, by calculating the photon component of the percentage depth dose at 10 cm depth with SSD 100 cm. RESULTS The calculated L̄/ρair (water) for beams without a flattening filter was 0.3% lower, on average, than for beams with a flattening filter and comparable TPR20,10. Using the relationship in IAEA, TRS-398 resulted in a root mean square deviation (RMSD) of 0.0028 with a maximum deviation of 0.0043 (0.39%) from Monte Carlo calculated values. For all beams in this study, the RMSD between the proposed model and the Monte Carlo calculated values was 0.0006 with a maximum deviation of 0.0013 (0.1%). Using an earlier proposed relationship [Xiong and Rogers, Med. Phys. 35, 2104-2109 (2008)] between %dd(10)x and L̄/ρair (water) gave a RMSD of 0.0018 with a maximum deviation of 0.0029 (0.26%) for all beams in this study (compared to RMSD 0.0015 and a maximum deviation of 0.0048 (0.47%) for the relationship used in AAPM TG-51 published by Almond et al. [Med. Phys. 26, 1847-1870 (1999)]). CONCLUSIONS Using TPR20,10 as a beam-quality specifier, for the flattening filter free beams used in this study, gave a maximum difference of 0.39% between L̄/ρair (water) predicted using IAEA TRS-398 and Monte Carlo calculations. An additional parameter for determining L̄/ρair (water) has been presented. This parameter is easy to measure; it requires only an additional dose measurement at 5 cm depth with SSD 95 cm, and provides information for accurate determination of the L̄/ρair (water) ratio for beams both with and without a flattening filter at the investigated energies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Access to the Published Version May Require Journal Subscription. Published with Permission From: American Association of Physicists in Medicine Prediction of Stopping-power Ratios in Flattening-filter Free Beams

This is an author produced version of a paper published in Medical Physics. This paper has been peer-reviewed but does not include the final publisher proof-corrections or journal pagination. "Prediction of stopping-power ratios in flattening-filter free beams." Abstract 25 Purpose: In recent years, there has been an increasing interest in flattening-filter free (FFF) beams. However, since the ...

متن کامل

Enhancement of the Dose on 12 MV Linac with Free Flattening Filter Mode

Purpose: In the last years, some studies investigated dosimetric benefits of a free flattening filter for the photon mode in the radiotherapy field. This study aims to provide a theoretical study published and analysis of basic dosimetric properties for a Saturne 43 Linac head to implement free flattening filter beams clinically. Material and Methods: Thi...

متن کامل

Dosimetric Comparison between 6MV Flattened Filter and Flattening Filter Free Photon Beams in the Treatment of Glioblastoma with IMRT Technique: A Treatment Planning Study

Introduction: The present study evaluated the dosimetric comparison between 6MV flattened filter (FF) and flattening filter-free (FFF) photon beams in intensity-modulated radiation therapy (IMRT) technique for the treatment of glioblastoma (GBM) patients. Material and Methods: The present study was conducted on 10 patients with GBM previously...

متن کامل

Investigation of Neutron Contamination of Flattening Filter and Flattening Filter-Free 10-MV Photon Beams in Elekta InfinityTM Accelerator

Introduction: This study aimed to measure the neutron contamination of flattening filter (FF) and flattening filter-free (FFF) 10-MV photon beams delivered by the Elekta InfinityTM accelerator. Material and Methods: The photoneutron spectrum produced by the Linac head was evaluated using a Monte Carlo (MC) simulation. The geometry ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2014