Accuracy and precision of "deep sternal" and tracheal temperatures at high- and low-fresh-gas flows.

نویسندگان

  • T Matsukawa
  • M Ozaki
  • D I Sessler
  • T Nishiyama
  • M Imamura
  • T Kumazawa
چکیده

The accuracy of tracheal temperature as a measure of core temperature is relatively poor during high-flow ventilation (6 litre min-1 fresh-gas flow). It is unknown if accuracy improves when lower fresh-gas flow rates are used. We tested the hypothesis that tracheal temperature accuracy would improve with low-flow ventilation (1 litre min-1). We studied 20 ASA Physical Status I and II patients undergoing general anaesthesia for lower abdominal surgery. Deep body temperatures were measured at the middle of the sternum using a Coretemp "deep-tissue" thermometer. Tracheal temperatures were monitored from thermistors incorporated into the tracheal tube cuffs. Oesophageal temperatures were measured from thermocouples incorporated into stethoscopes positioned at the point of maximal heart sounds. Sternal temperature correlated reasonably well with distal oesophageal temperatures, both being within the 0.5 degree C cut-off for accuracy and precision. Tracheal temperatures were lower than oesophageal temperatures during both high- and low-flow ventilation. Tracheal temperatures were 0.7 degree C less during high-flow ventilation and 0.9 degree C less during low-flow ventilation. The precision in both cases was adequate. We conclude that tracheal temperatures were insufficiently accurate for routine clinical use, even when fresh- gas flow was restricted to 1 litre min-1. In contrast, the deep temperatures were sufficiently accurate and precise for routine clinical use.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A preconditioned solver for sharp resolution of multiphase flows at all Mach numbers

A preconditioned five-equation two-phase model coupled with an interface sharpening technique is introduced for simulation of a wide range of multiphase flows with both high and low Mach regimes. Harten-Lax-van Leer-Contact (HLLC) Riemann solver is implemented for solving the discretized equations while tangent of hyperbola for interface capturing (THINC) interface sharpening method is applied ...

متن کامل

Vancomycin Local application, role in Deep Sternal Wound Infection in our experience

Introduction: Deep sternal wound infection (DSWI) is one of the most complex and potentially devastating complications following median sternotomy in cardiac surgery. Despite many advances in prevention, it still remains significant and ranges between 0.5% and 6.8%. We aim to study the role of vancomycin paste applied locally over sternal edges in reducing DSWI.Materials and Methods...

متن کامل

The effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows by Lattice-Boltzmann method

The aim of this study is to investigate the effect of boundary conditions on the accuracy and stability of the numerical solution of fluid flows in the context of single relaxation time Lattice Boltzmann method (SRT-LBM). The fluid flows are simulated using regularized, no-slip, Zou-He and bounce back boundary conditions for straight surfaces in a lid driven cavity and the two-dimensional flow ...

متن کامل

Introduction of low to high frequencies bispectrum rate feature for deep sleep detection from awakening by electroencephalogram

Background: Accurate detection of deep sleep (Due to the low frequency of the brain signal in this part of sleep, it is also called slow-wave sleep) from awakening increases the sleep staging accuracy as an important factor in medicine. Depending on the time and cost of manually determining the depth of sleep, we can automatically determine the depth of sleep by electroencephalogram (EEG) signa...

متن کامل

بررسی عفونت استرنوم متعاقب جراحی عروق کرونر در مرکز قلب مازندران

Background and purpose: Sternal Wound Infection (SWI) is a serious complication of median sternotomy that increases the rate of mortality. We report our experience of managing SWI in a regional cardiothoracic unit in Mazandaran province, Iran. Materials and methods: We prospectively studied 4725 patients who underwent isolated coronary artery bypass grafting between March 2012 and March 2015...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 1998