Correlation of environmental carbaryl measurements with serum and urinary 1-naphthol measurements in a farmer applicator and his family.

نویسندگان

  • D B Shealy
  • J R Barr
  • D L Ashley
  • D G Patterson
  • D E Camann
  • A E Bond
چکیده

In exposure or risk assessments, both environmental and biological measurements are often used. Environmental measurements are an excellent means for evaluating regulatory compliance, but the models used to estimate body burden from these measurements are complex. Unless all possible routes of exposure (i.e., inhalation, dermal absorption, ingestion) are evaluated, exposure to a toxicant can be underestimated. To circumvent this problem, measurements of the internal dose of a toxicant in blood, serum, urine, or tissues can be used singularly or in combination with environmental data for exposure assessment. In three separate laboratories, carbaryl or its primary metabolite, 1-naphthol, was measured in personal air, dermal samples, blood serum, and urine from farmer applicators and their families. The usefulness of both environmental and biological data has been demonstrated. For the farmer applicator, the environmental levels of carbaryl would have been sufficient to determine that an exposure had occurred. However, biological measurements were necessary to determine the absorbed dose of each member of the applicator's family. In addition, a correlation between serum and urinary 1-naphthol measurements has been shown; therefore, either matrix can be used to accurately evaluate occupational carbaryl exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Urinary Naphthol as a Biomarker of Exposure: Results from an Oral Exposure to Carbaryl and Workers Occupationally Exposed to Naphthalene

Urinary naphthol is an established human biomarker used for assessing both occupational and environmental exposure. However, 1-naphthol is a metabolite of the insecticide carbaryl while both the 1- and 2-isomers are metabolites of naphthalene. Thus, urinary 1-naphthol levels will reflect combined exposure to both substances, particularly at environmental levels. The interpretation of biomarkers...

متن کامل

The Relationship of Urinary Metabolites of Carbaryl/Naphthalene and Chlorpyrifos with Human Semen Quality

Most of the general population is exposed to carbaryl and other contemporary-use insecticides at low levels. Studies of laboratory animals, in addition to limited human data, show an association between carbaryl exposure and decreased semen quality. In the present study we explored whether environmental exposures to 1-naphthol (1N), a metabolite of carbaryl and naphthalene, and 3,5,6-trichloro-...

متن کامل

Simultaneous determination of carbaryl and 1-naphthol by first-derivative synchronous non-protected room temperature phosphorescence.

The applicability of non-protected room temperature phosphorescence (NP-RTP) in real samples was demonstrated in the present work. In this methodology, only two reagents, potassium iodide and sodium sulfite, were used to obtain phosphorescent signals. Overlapping of the phosphorescence spectra was resolved by using first-derivative synchronous phosphorimetry. The synchronous first-derivative sp...

متن کامل

Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter

Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being used for radiotherapy treatment. Materials and Methods: Computerized 3-D water phantom of multi-data system was used. The measurements were made...

متن کامل

Evaluation of a Multicommuted Flow System for Photometric Environmental Measurements

A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25 cm x 22 cm x 10 cm, weighs circa 3 kg, and costs 650 euro. System performance was evaluated for different chemistries without changing hardware c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 105  شماره 

صفحات  -

تاریخ انتشار 1997