Preliminary evaluation of near-infrared vein visualization technology in the screening of palatal blood vessels

نویسندگان

  • Emre Yaprak
  • Sibel Kayaalti-Yuksek
چکیده

BACKGROUND Avoidance from palatal blood vessel rupture is a major concern during the palatal soft tissue graft surgery. There is no defined chair-side and case-specific palatal blood vessel detection approach to facilitate the harvesting process. The objective of this pilot study is to assess the feasibility of a near-infrared vein visualization system in the screening process of palatal blood vessels. MATERIAL AND METHODS An extraoral vein visualization device (AccuVein AV400) was applied to a total of 304 hemi-maxilla of 152 individuals by two blind examiners. The study groups were classified according to their maximum inter-incisal measurements. The distances between the coronal border of the vessel image and the mid-palatal gingival margins of the adjacent teeth were measured and in each group. The correlations among the measurements were evaluated within groups. RESULTS The blood vessel to the adjacent teeth measurements exhibited no statistical difference between both examiners in all subjects (p<0.001). Correlations between the examiners gradually increased in all groups as the mouth opening rates of the subjects were increased (p<0.001). CONCLUSIONS In the current state, screening of the palatal blood vessels via near-infrared vein visualization technology seems to be not suitable for every individual due to the restrictive effect of mouth opening. However, the promising results of this preliminary study demonstrated increasing consistency between the measurements of the examiners as the inter-incisal distance increase which emphasized the need an intraoral version of the device. Considering the lack of local decision-making technology for the detection of palatal blood vessels, further studies are required for development and optimization of these systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy

Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Determining Blood Glucose Concentration using Near Infrared Spectroscopy: Early Findings

Introduction: Diabetes mellitus is one of the diseases that have grown dramatically in today's societies. People with diabetes should continuously measure their blood glucose level. Continuous blood glucose measurement by commonly used methods is painful and difficult. On the other hand, mobile phone can be a useful tool for accessing physicians and telemedicine services more easily. The aim of...

متن کامل

Localization and quantification of platelet-rich thrombi in large blood vessels with near-infrared fluorescence imaging.

BACKGROUND Imaging of thrombus formation in vivo has been limited by the inability to directly visualize and measure thrombi in large blood vessels in real time. Near-infrared light, with its superior tissue penetration and reduced scatter, could potentially solve this problem. METHODS AND RESULTS Platelets were labeled with the near-infrared fluorophore IR-786. Optimal total fluorescence yie...

متن کامل

Near-Infrared Emitting PbS Quantum Dots for in Vivo Fluorescence Imaging of the Thrombotic State in Septic Mouse Brain.

Near-infrared (NIR) fluorescent imaging is a powerful tool for the non-invasive visualization of the inner structure of living organisms. Recently, NIR fluorescence imaging at 1000-1400 nm (second optical window) has been shown to offer better spatial resolution compared with conventional NIR fluorescence imaging at 700-900 nm (first optical window). Here we report lead sulfide (PbS) quantum do...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2018