Catheter Ablation of Arrhythmias Exclusively Using Electroanatomic Mapping: A Series of Cases

نویسندگان

  • Leonardo Martins Pires
  • Tiago Luiz Luz Leiria
  • Marcelo Lapa Kruse
  • Rafael Ronsoni
  • Caroline Saltz Gensas
  • Gustavo Glotz de Lima
چکیده

BACKGROUND Catheter ablation is a treatment that can cure various cardiac arrhythmias. Fluoroscopy is used to locate and direct catheters to areas that cause arrhythmias. However, fluoroscopy has several risks. Electroanatomic mapping (EAM) facilitates three-dimensional imaging without X-rays, which reduces risks associated with fluoroscopy. OBJECTIVE We describe a series of patient cases wherein cardiac arrhythmia ablation was exclusively performed using EAM. METHODS Patients who presented with cardiac arrhythmias that were unresponsive to pharmacological therapy were prospectively selected between March 2011 and March 2012 for arrhythmia ablation exclusively through EAM. Patients with indications for a diagnostic electrophysiology study and ablation of atrial fibrillation, left atrial tachyarrhythmias as well as hemodynamically unstable ventricular arrhythmia were excluded. We documented the procedure time, success rate and complications as well as whether fluoroscopy was necessary during the procedure. RESULTS In total, 11 patients were enrolled in the study, including seven female patients (63%). The mean age of the patients was 50 years (SD ± 16.5). Indications for the investigated procedures included four cases (35%) of atrial flutter, three cases (27%) of pre-excitation syndrome, two cases (19%) of paroxysmal supraventricular tachycardia and two cases (19%) of ventricular extrasystoles. The mean procedure duration was 86.6 min (SD ± 26 min). Immediate success (at discharge) of the procedure was evident for nine patients (81%). There were no complications during the procedures. CONCLUSION This study demonstrates the feasibility of performing an arrhythmia ablation exclusively using EAM with satisfactory results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopy-Free Electrophysiology Study Using 3D Electroanatomic Mapping System: A Case Report and Review of Literature

Due to the use of fluoroscopy in the electrophysiology lab, long and complex procedures to diagnose and treat cardiac arrhythmias can lead to radiation exposure to both patients and the laboratory staff. In this report, we present a case in which a diagnostic electrophysiology study was conducted on a 41 year-old patient with atrial tachycardia without the use of fluoroscopy. The diagnostic com...

متن کامل

Catheter ablation of cardiac arrhythmias guided by electroanatomic imaging (CARTO): a single-center experience.

BACKGROUND Catheter ablation is assuming a larger role in the management of patients with cardiac arrhythmias. Conventional fluoroscopic catheter mapping has limited spatial resolution and involves prolonged fluoroscopy. The non-fluoroscopic electroanatomic mapping technique (CARTO) has been developed to overcome these drawbacks. OBJECTIVES To report the early and late outcome in patients wit...

متن کامل

Catheter ablation of supraventricular tachycardia in the transplanted heart: a case series and literature review.

Clinically important supraventricular arrhythmias are occasionally encountered in patients following cardiac transplantation and the use of catheter ablation as a treatment has been reported. The following three cases are described: (1) atrial flutter, including electroanatomic mapping of the donor and recipient components of the right atrium, (2) a mid-septal accessory pathway, and (3) atriove...

متن کامل

Electroanatomic mapping: the 21st century approach to treating cardiac arrhythmias.

• Vol 9 • April 2007 326 Catheter ablation using radiofrequency energy was developed in the late 1980s and was described in the literature in 1991 [1,2]. Within a short time the procedure gained acceptance and became widely practiced because of the high success rate and reduced complication rate assured by this titrable and controllable energy [3]. This ablation method was applied to treat the ...

متن کامل

CARTO three-dimensional non-fluoroscopic electroanatomic mapping for catheter ablation of arrhythmias: a useful tool or an expensive toy for the electrophysiologist?

This review enlightens the application issues of the novel CARTO electroanatomic mapping system (Biosense Webster, Diamond Bar, CA, USA) in both research and clinical electrophysiology. It is a very useful tool in catheter ablation procedures in patients with sustained atrial tachycardias, macroreentrant atrial arrhythmias after surgical correction of congenital heart disease, and ventricular t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 101  شماره 

صفحات  -

تاریخ انتشار 2013