Determination of creatinine in serum and urine by cation-exchange high-pressure liquid chromatography.
نویسندگان
چکیده
We describe an HPLC method for quantifying creatinine, separating the analyte from other compounds in serum and urine by cation-exchange chromatography and measuring its absorbance at 234 nm. The precision of the method (CV) varied from 2.9% (mean creatinine concentration, 31 mumol/L) to 1.7% (361 mumol/L) within a series of assays and from 3.9% (34 mumol/L) to 2.4% (391 mumol/L) between series. A comparison with the Jaffé method, as performed with a Technicon SMA analyzer, gave the regression line yHPLC = 1.00xJaffé - 12.0 (n = 141, r = 0.998, and Syx = 19). Results also are comparable with those of an enzymatic method, if the enzymatic method is standardized with a serum-based standard when serum samples are measured. An aqueous standard has to be used for enzymatic determination of creatinine in urine.
منابع مشابه
Serum creatinine determination by high performance liquid chromatography and five automated chemistry analyzers.
A sensitive and specific procedure is described for the determination of serum creatinine by reverse phase high performance liquid chromatography. The method involves sample pretreatment with a cation exchange resin followed by the isocratic separation of creatinine and an external standard which are detected by their absorbances at 254 nm. The analytical recovery of creatinine from serum was 9...
متن کاملDetermination of creatinine in human serum by isotope dilution-mass spectrometry. Definitive methods in clinical chemistry, IV.
A method for the determination of creatinine in human serum by isotope dilution-mass spectrometry is described. The analytical procedure comprises the following steps: Addition of [13C,15N2 )creatinine to the serum sample; ion exchange chromatography on the cation exchange resin AG 50W-X2; formation of the trimethylsilyl derivative; gas liquid chromatography-mass spectrometry (GC-MS); selected ...
متن کاملSimultaneous determination of 8-hydroxydeoyguanosine, a marker of oxidative stress, and creatinine, a standardization compound, in urine.
Recently, H. Kasai reported an automatic, precise method of 8-hydroxydeoxyguanosine (8-OH-dG) analysis in urine by high performance liquid chromatography coupled to an electrochemical detector (HPLC-ECD). It is based on a cleaning-up step by anion-exchange chromatography and a further purification step using reverse phase chromatography before detection, by the ECD. In this communication, we re...
متن کاملHPLC with enzymatic detection as a candidate reference method for serum creatinine.
We present a candidate Reference Method for determining the concentration of serum creatinine. The method is based on HPLC combined with enzymatic determination. Creatinine plus 14[C]creatinine is extracted by cation-exchange chromatography, subjected to reversed-phase HPLC, and finally quantified enzymatically. Enzymatic measurement ensures no interference from co-eluting compounds, which has ...
متن کاملDetermination of "true" serum creatinine by high-performance liquid chromatography combined with a continuous-flow microanalyzer.
We coupled a high-performance liquid chromatograph with a continuous-flow microanalyzer to produce a system for specifically determinig "true" creatinine in urine and serum specimens. A selective microbore pellicular cation-exchange column and a single eluting sodium citrate buffer are used to separate the noncreatinine but Jaffé-positive constituents from the creatinine in normal and experimen...