Repetition of Examination Due to Motion Artifacts in Horizontal Cone Beam CT: Comparison among Three Different Kinds of Head Support
نویسندگان
چکیده
AIMS AND OBJECTIVES The aim of this study was to evaluate the repetition rate of examination due to motion artifacts in horizontal cone beam computed tomography, using three different kinds of head support, with reference to the patient's age. Further purpose was to evaluate how comfortable head supports were. MATERIALS AND METHODS Seven hundred and fifty patients underwent a maxillofacial/dental arches volumetric imaging scan. They were divided into three groups depending on the head support used: foam headrest, foam headrest with head strap, and head restraint helmet. Each group was subdivided into three age groups: ≤18-year-old, 19-65-year-old, and ≥66-year-old patients. A severity index of motion artifacts, divided into four tiers from absence to remarkable artifacts, was adopted. Finally, each patient gave their judgment about the head support comfort by a questionnaire including ten yes/no questions. A three-score scale (insufficient, sufficient, and good) was used to judge the comfort. Collected data were analyzed using the SPSS® version 23.0 statistical analysis software. RESULTS Forty-one patients (5.4%) repeated the examination. In 16 (2.1%), 15 (2.0%), and 10 (1.3%) of them, foam headrest, foam headrest with head strap, and head restraint helmet were used, respectively. Examination was repeated in 5.3%, 3.8%, and 10.6% in ≤18-year-old, 19-65-year-old, and ≥66-year-old patients, respectively. Patients almost always judged good the comfort for each kind of support. The lowest percentage of satisfaction was observed for the headrest with head strap and was judged good in 78% of the cases. CONCLUSIONS The repetition rate of examination showed similar values among the foam headrest, foam headrest with head strap, and head restraint helmet in under 66-year-old patients. In over 65-year-old patients, the head restraint helmet obviously decreased the repetition rate of examination. All three head supports were good comfort, especially the foam headrest.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملبررسی مقایسهای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازهگیری ضایعات استخوانی پریودنتال
Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملEffective One Step-iterative Fiducial Marker-based Compensation for Involuntary Motion in Weight-bearing C-arm Cone-beam CT Scanning of Knees
We previously introduced three different fiducial marker-based correction methods (2D projection shifting, 2D projection warping, and 3D image warping) for patients’ involuntary motion in the lower body during weight-bearing Carm CT scanning. The 3D warping method performed better than 2D methods since it could more accurately take into account the lower body motion in 3D. However, as the 3D wa...